![AR 10012514 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/ar/10012514/10012514_operating-and-service-manual_2962271041.webp)
Table 3-6. Catalog of System State Codes
(The RDLOGIC command causes the TWTA to send a string containing an operational state code consisting of 4
ASCII characters representing hex digits. The response is in the form
Sys:
[w][x][y][z][eol]
where the hex values
of
[w],[x],[y] and [z]
are formed as shown below)
z bit
Meaning
0 (LSB)
High voltage on
1 Transmit
on
2 Remote
mode
3 (MSB)
Fault
y bit
Meaning
4 (LSB)
Heater time delay expired
5
Under forward power warning
6 Foldback
active
7 (MSB)
Inhibit mode
x bit
Meaning
8 (LSB)
External inhibit
9 Interlock
open
10 (not
used)
11 (MSB)
(not used)
w bit
Meaning
12 (LSB)
(not used)
13
Sleep Mode Active
14 (not
used)
15 (MSB)
(not used)
Table 3-7. *STA?; Response Codes
(The command *STA?; causes the TWTA to send a string indicative of the current system state)
*STA?; response
Meaning
SLEEP
Sleep Mode active (heater off)
WARM-UP
System is in heater time delay.
STANDBY
System is ready to allow high voltage on
OPERATE
High voltage is on and beam is on
FAULT
High voltage is off and system requires reset
Rev A
23
Содержание 10012514
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 46: ...Model 300T2G8 28 Rev A...
Страница 50: ...Model 300T2G8 32 Rev A...
Страница 54: ...Model 300T2G8 36 Rev A...
Страница 55: ...5 3 WIRING DIAGRAMS 20 22520 000 TWT Power Supply 10 1 2 Series A22520 052 Rev A 37...