33
© 2009 Aquathin Corporation. All rights reserved.
Replacing the Aquathin DI Module
(Refer to page 47, Appendix C, for details on releasing
tubing from Speedfit® fittings)
1) Disconnect the tubing from both ends of the DI
module. Some water will pour from the tubing once
released. (If the DI module was mounted vertically,
you might find less water will be spilled if you
remove the tubing from the outlet end after removing
the module from the retaining clamp.)
2) Remove the top screw from the clamp and remove
the old DI module. (The clamp is flexible and can be
bent out to allow the module to be removed.) Note
the direction of flow. You will need to install the
new DI module in the same orientation.
3) Unscrew the Speedfit® fittings from both ends of the
module. Scrape away the old Teflon® thread tape
(without damaging the plastic threads) and re-wrap
the threads.
4) Install the Speedfit® fittings into the new DI
module.
5) Place the new DI module into position, taking care to
note the direction of flow. Secure the clamp and re-
connect only the tubing from the main assembly.
Gently tug on the tubing to insure a secure, leak free
connection.
The next step will disinfect and sterilize the storage tank:
6) Carefully place a few drops of regular household
bleach into the tubing that connects the outlet of the
DI module with the storage tank before connecting
the tubing to the DI module. (As the tank fills with
water for the first time, it will be subjected to a
strong but continually diluting solution of chlorine.)
Содержание AquaKING RO
Страница 45: ...45 2009 Aquathin Corporation All rights reserved Maintenance Log Module Replaced Date ...
Страница 46: ...46 2009 Aquathin Corporation All rights reserved Connections Sink Mounted Faucet Assembly ...
Страница 50: ...50 2009 Aquathin Corporation All rights reserved ...
Страница 51: ...51 2009 Aquathin Corporation All rights reserved ...
Страница 52: ...52 2009 Aquathin Corporation All rights reserved EPA EST NO 52531 FL 01 ...