34
© 2009 Aquathin Corporation. All rights reserved.
Alternate disinfection procedure:
a) Disconnect the tubing from the “T” connector on the
tank ball valve and remove the storage tank from
beneath the sink.
b) Wrap a towel around the ball valve and slowly
unscrew the valve from the storage tank. There is
always some water remaining in the tank and this
will escape when the valve is removed. After setting
the valve aside, place the towel over the tank
opening and shake and rotate the tank to remove any
remaining water.
c) Re-wrap the threads with Teflon® pipe tape.
d) Now place a few drops of liquid chlorine bleach into
the top of the tank and re-install the tank ball valve (with
the valve in the closed position).
e) Reconnect the tubing to the swivel “T” connector.
Returning the AquaKING System to Service
To return your system to service:
1. Verify the manual flush valve is in the “Open -
Flush” position.
2. Open the valve on top of the storage tank.
3. Slowly re-open the cold water supply line. The pre-
filter canisters should begin to fill.
4. After ten (10) minutes, move the manual flush valve
to the “Closed - Production” position.
5. Check for leaks around the tops of the pre-filter
canisters. If water is seeping from any of the
canisters turn the cold water supply off, move the
manual flush valve to the “Flush” position, and then
Содержание AquaKING RO
Страница 45: ...45 2009 Aquathin Corporation All rights reserved Maintenance Log Module Replaced Date ...
Страница 46: ...46 2009 Aquathin Corporation All rights reserved Connections Sink Mounted Faucet Assembly ...
Страница 50: ...50 2009 Aquathin Corporation All rights reserved ...
Страница 51: ...51 2009 Aquathin Corporation All rights reserved ...
Страница 52: ...52 2009 Aquathin Corporation All rights reserved EPA EST NO 52531 FL 01 ...