If Low Power Logging Mode was selected (Status set to
LOW POWER
), the Meter will
switch itself off 30 seconds after your last key-press. Thereafter it will switch back on at the
set rate, stay on for 30 seconds, log the data, then switch back off again. This will be
repeated until either the memory is full or the batteries go flat.
If you press any key while the Meter is off between readings in low power mode, the Meter
will switch back on. If no further key is pressed, the Meter will switch back off again after 30
seconds and resume Low Power Mode.
You can cancel Auto Data Logging at any time by going back into the screen above and
setting the
Status
to
OFF
. Auto Data Logging will also be cancelled if you switch the Meter
off manually.
8.6. Battery and Memory Duration in Low Power Logging Mode
Low Power Logging Mode is specifically designed for long term data logging. In order to
estimate battery life and memory usage, the following table can be used.
The battery life figures quoted below are based on fresh, good quality alkaline batteries at
a Meter temperature of 21°C or over. Colder Meter temperatures will drastically reduce the
battery life. For example, at 5°C, the battery life will be approximately half that quoted.
Logging Rate
Battery Life (at 21°C)
Memory Duration
90 mins
38 Days
66 Days
60 mins
36 Days
44 Days
45 mins
34 Days
33 Days
30 mins
30 Days
22 Days
15 mins
20 Days
11 Days
5 mins
10 Days
3.6 Days
1 min
2 Days
17 Hours
So, it can be seen that although the Meter has a maximum data capacity of 66 days, for
logging rates above 45 minutes, fresh batteries would need to be fitted after approximately
one month in order to make use of the Meter's full memory capacity.
Conversely, logging rates below 45 minutes will fill the Meter's memory on a single set of
batteries (at 21°C or greater).
Useful Tip:
If you want GPS data logged in association with your other data, ensure the
Meter is positioned face up with a clear view of the sky.