10. Note:  In the unlikely event the UV bulb needs replacing, remove glass 

tube by pulling straight apart by holding the base of the lamp.  Gently 
pull bulb straight apart from the bulb socket and insert the replacement 
bulb in the reverse manner careful not to bend the wires at the stem of 
the bulb.  Fig. 14 

 
 
 
 
 
 
 

                                                                                                                                                   

Fig. 14 

 

11. Clean the exterior of the UV glass tube with warm soapy water.  

 Fig. 15 

 
 
 
 
 
 
 
 

                                                                                                                                                   

Fig. 15 

12. 

Reassemble all of the components (Notes: Don’t forget connect the 
low voltage power cables), place the unit into the water and connect to 
a proper power source.    Fig. 16 

 
 
 
 
 
 
                                                                                                                                                 

Fig. 16 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

UV Bulb 

Glass tube 

 

 

Clean with soap 

 

GFCI 

Содержание QFUVP

Страница 1: ...lectrical shock This unit has not been investigated for use in swimming pools or marine areas CAUTION This unit has been evaluated for use with water only Use a proper power source as indicated on the...

Страница 2: ...hot tubs PREPARATION Before beginning assembly or operation of product make sure all parts are present Compare parts with package contents list and diagram above If any part is missing or damaged do...

Страница 3: ...ure optimal operation of the Floating Pump and Filter with UV the following procedures should be performed periodically When the performance of the water flow through the fountain head is reduced it i...

Страница 4: ...Pump and Filter assembly upside down Remove the locking screw Fig 7 Fig 7 4 Remove the fountain head and the top locking nut Then remove the top cover Fig 8 Fig 8 5 Twist the top section counterclock...

Страница 5: ...the pump unscrew the wire connector that connects the UV light assembly to pump Fig 11 Fig 11 8 Disassemble the pump clean parts of the pump in warm soapy water then reassemble the pump Fig 12 Fig 12...

Страница 6: ...pull bulb straight apart from the bulb socket and insert the replacement bulb in the reverse manner careful not to bend the wires at the stem of the bulb Fig 14 Fig 14 11 Clean the exterior of the UV...

Страница 7: ...h can cause damage to the light unit 1 Disconnect the UV light from the outlet Be sure to allow sufficient time for the light to cool before disassembling the light 2 Unscrew the locking ring and pull...

Страница 8: ...B Waterspray nozzle C Waterbell nozzle insert D Trumpet nozzle insert E Lower fountain head nozzle F pumpshield G Flow control knob H Front cover I Locking ring J Impeller cover K O ring L Shaft supp...

Страница 9: ...iated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral stat...

Отзывы: