Before returning to your retailer, call our customer service department at  
1-888-314-2588, 8 a.m.-6 p.m., EST, Monday-Friday.   
 

 

CARE AND MAINTENANCE 

 

General 

 

A visible drop in waterflow or increased algae in the pond is your indication that filter 
pad, pump, and/or UV clarifier portion of the unit require cleaning.   

 

Before  attempting  to  disassemble  the  unit  or  clean  the  pump,  UV  clarifier  or  any 
portion of the unit, always disconnect the unit from the power source.   

 

Disassemble  the  unit  in  accordance  with  the  Disassembly  Procedure  section  of  this 
instruction sheet. 

 

Cleaning the Pump 

 

Insure the pump is disconnected from all other components comprising the unit. 

 

Inspect the pump by removing the front screen and impeller assembly and clean parts 
of the pump and clean in warm, soapy water. 

 

Reassemble the pump and reposition and connect the low voltage power cables 

 

 
 

 

 

 
 
 
 

                                         Fig. 17 

To maximize the performance of the UV clarifier portion of the unit, periodically disassemble the unit to 
clean dirt and debris from the exterior of the glass tube and reflector located in the lamp housing. 
 

IMPORTANT NOTE: 

Be sure that the entire unit is completely dry and gaskets are properly seated when reassembling the UV 
clarifier.   
Failure to do so will result in water leakage, which can cause damage to the light unit.   
 
1.  Disconnect the UV light from the outlet.  Be sure to allow sufficient time for the light to cool before 

disassembling the light. 

2.  Unscrew the locking ring, and pull out the light unit.  
3.  Carefully pull out the glass tube holder by twisting and then pull out.    
4.  Use warm, soapy water to clean the glass tube.  Be sure to use biodegrable soap. 
5.  Reassemble the UV clarifier, and be sure that all gaskets and o-rings are seated properly. 

 

TROUBLESHOOTING  

If the LED lights fail to operate: 

 

Check to make sure the power cord is plugged in and the light is getting power and the unit is 
getting power. 

    If the UV Clarifier fails to operate: 

 

Check bulb to make sure that it has not burned out.  Replace the bulb as necessary or after 
every season. Bulbs are available by calling the customer service department. 

If the pump fails to operate: 

 

Check to make sure the power cord is plugged in, the pump is getting power and the pump is 
fully submerged. 

 

Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn 
the impeller to ensure that it is not broken or jammed. 

If the performance of the pump is not satisfactory or the pump does not flow evenly: 

 

Check to make sure the pump is completely submerged in water. 

 

Check to make sure the impeller, filter pad and the housing are clean clear of debris. 

 

Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions. Adjust 
flow control. 

Содержание QFUVP

Страница 1: ...lectrical shock This unit has not been investigated for use in swimming pools or marine areas CAUTION This unit has been evaluated for use with water only Use a proper power source as indicated on the...

Страница 2: ...hot tubs PREPARATION Before beginning assembly or operation of product make sure all parts are present Compare parts with package contents list and diagram above If any part is missing or damaged do...

Страница 3: ...ure optimal operation of the Floating Pump and Filter with UV the following procedures should be performed periodically When the performance of the water flow through the fountain head is reduced it i...

Страница 4: ...Pump and Filter assembly upside down Remove the locking screw Fig 7 Fig 7 4 Remove the fountain head and the top locking nut Then remove the top cover Fig 8 Fig 8 5 Twist the top section counterclock...

Страница 5: ...the pump unscrew the wire connector that connects the UV light assembly to pump Fig 11 Fig 11 8 Disassemble the pump clean parts of the pump in warm soapy water then reassemble the pump Fig 12 Fig 12...

Страница 6: ...pull bulb straight apart from the bulb socket and insert the replacement bulb in the reverse manner careful not to bend the wires at the stem of the bulb Fig 14 Fig 14 11 Clean the exterior of the UV...

Страница 7: ...h can cause damage to the light unit 1 Disconnect the UV light from the outlet Be sure to allow sufficient time for the light to cool before disassembling the light 2 Unscrew the locking ring and pull...

Страница 8: ...B Waterspray nozzle C Waterbell nozzle insert D Trumpet nozzle insert E Lower fountain head nozzle F pumpshield G Flow control knob H Front cover I Locking ring J Impeller cover K O ring L Shaft supp...

Страница 9: ...iated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral stat...

Отзывы: