44
10.2
Default settings VZF II / VZFA II
Total counter mass
unit selected in Unit volume
Trip counter mass
unit selected in Unit volume
Actual mass flow
unit selected in Unit volume and Unit time
Total counter
unit selected in Unit volume
Trip counter
unit selected in Unit volume
Actual flow
unit selected in Unit volume and Unit time
Temperature
medium temperature in unit selected in Unit temperature
Total counter dist. Fuel
unit selected in Unit volume
Trip counter dist. Fuel
unit selected in Unit volume
Total counter Heavy Fuel
unit selected in Unit volume
Trip counter Heavy Fuel
unit selected in Unit volume
Total counter Lube oil
unit selected in Unit volume
Trip counter Lube Oil
unit selected in Unit volume
Setup menu
Unit volume
L
, G, m
3
Unit time
s, min,
h
Unit temperature
°C
, °F
Unit mass
kg
, t, lb
Nominal size*
15,
20
, 25, 40, 50
Measuring chamber*
default: per selected size, or calibrated value
Trip Reset
Reset yes / no
yes
, no
Low flow cut off
Qstart
, 0...Qmin
Compensation
off
, on
Mass Compensation
off
, on
Oil Fuel
Oil Fuel
, Oil Lube
°t Limit
60°C
, 0…200°C (32…392°F)
dd__kg/m3
880kg/m
3
,
800…1200kg/m
3
(@ 15°C, Bunkerreport)
dH__kg/m3
990kg/m
3
,
800…1200kg/m
3
(@ 15°C, Bunkerreport)
dL__kg/m3
900kg/m
3
,
800…1200kg/m
3
(@ 15°C, Bunkerreport)
Output 1
Volume
, Flow, Mass, Mass Flow, Limit, State, off
Volume output
Pulse width
50ms
, 2...500ms
Unit per pulse
1UPP
, 0.001...1000UPP
[0.1UPP DN15]
Simulation
off
, on
Sim value
0…Qmax (max. 9999.9)
Actual output
display flashes [Act Pulse] when active
Flow output
Min Flow
Qmin
, 0...Qmax
Min Frequency
20Hz
, 1...200Hz
Max Flow
Qcont
, 0...Qmax
Max Frequency
200Hz
, 1...200Hz
Error behavior
FMA
, Act
Simulation
off
, on
Sim Value
0…Qmax (max. 9999.9)
Actual output
displays actual frequency on output [Act Hz] when active