CONTOIL

®

 DFM

     

1.   With the DFM-BC in front of you, open the side-wings of the box and unscrew the 4 screws. Put the upper part of  

     

    the DFM-System gently a side. Be CAREFULL. The upper part is connected to the base part with a flat cable.

     

2.   Look at the print on the base. You will see a connector with 14 positions.

     

    To ensure a proper function, this cable 

must be 

connected directly to the vehicle’s battery. Do not connect it  

     

     over the start-key of the vehicle. That means, also with the vehicle’s key in your pocket the DFM-BC must be electri-

     

    cal powered. The consumption of the electrical power is far below 1mA.

     

3.   Connect a two wire cable (0.75 mm

2

) from the vehicle battery, through one of the gland, to the position 

     

    13 (Batt. plus) and position 14 (Batt. minus). Tighten the gland-nut very well by hand, until the cable is fixed.

     

    To ensure a proper function, this cable must have a direct connection to the battery. Do not connect it over the 

   

  start-key 

of 

the 

vehicle.

     

4.   Take the cable from the Auxiliary and pass it through one of the gland of the DFM-BC. Tighten the gland-nut very  

     

    well by hand, until the cable is fixed.

     

5.   Connect the cable according to the table below:

   

DFM-BC  

 

 

Fleet-Manager or 

   

positions on the connector   

GPS Tracking-System

     

11 (Signal Output) 

to 

Signal or Digital/Analog Input

   

12 

(Ground) 

 

to 

Ground

     

For more information see section “Electrical connections and Specifications”

 
     

6.   After all cables are connected and well in place, put the upper part of the DFM-BC back on the base part and 

   

  screw 

it 

down.

     

7.   Take the DFM-BC. If it is off, press one of the 4 Keys on the front to reactivate it. Go to the menu point <Service>.

     

    Press <OK> and enter the Service-Code. Standard service code is: 1111.

     

8.   Set the Auxiliary (AUX) active.

   

  a. 

Press 

the 

 down-arrow to move to the <AUX> line.

     

    b. On the line “AUX”, press <OK>. Modify the value by using the 

 down-arrow or the 

 up-arrow.

     

    c. Change the value to <Yes>

     

    d. Press <OK> to confirm the modification.

   

  e. 

Exit 

with 

<ESC>.

     

9.   From this point the signal will be send to the auxiliary port of the DFM-BC and the word AUX will be  displayed on  

     

    the DFM-BC Display in big letters. No more information on the DFM-BC screen will be available until you 

   

  deactivate 

the 

<AUX>.

     

10.  Set the Fleet-Manager or the GPS-System input according to the “Output Value” set during the installation of the  

   

  flow 

meters.

Flow meters to Fuel Counter other than the DFM Board Computer (DFM 8D / 20S / 25S)

     

1.   Go to section <Electrical Connections and Specifications> and install the DFM flow meters according to the 

     

    specification of the used Fuel Counter.

     

2.   Go to the section “Startup (commissioning)”

DFM-BC connection to other flow meter(s) other than the DFM flow meter(s).

     

For differential measurement

     

Supply Line flow meter

     

1. Connect the “Signal” cable from the flow meter 1 to the pin 3 of the DFM-BC

     

2. Connect the “Ground” cable from the flow meter 1 to the pin 2 of the DFM-BC

     

Return Line flow meter

     

3. Connect the “Signal” cable from the flow meter 2 to the pin 9 of the DFM-BC

     

4. Connect the “Ground” cable from the flow meter 2 to the pin 8 of the DFM-BC

     

For direct measurement

     

1. Connect the “Signal” cable from the flow meter to the pin 3 of the DFM-BC

     

2. Connect the “Ground” cable from the flow meter 1 to the pin 2 of the DFM-BC

Содержание CONTOIL DFM 20S

Страница 1: ...Hours Return Line information about Total TRIP Current l h Op Hours Consumption Overview results from Supply Line minus Return Line Supply Configuration Return Configuration Error Log Entry Error Log...

Страница 2: ...distributor will supply you with current infor mation and updates to these Operating Instructions Return of the instruments The following procedures must be carried out before a device requiring repai...

Страница 3: ...arrow on the flow meters must be show in the flow direction The flow meters must be absolutely free of gas inclusions High pressure hammers from injection pump have to be avoided on flow meters for e...

Страница 4: ...DFM BC must be electrically powered The power consumption is far below 1mA 5 Connect a two wire cable 0 75 mm2 from the vehicle battery through one of the gland of the DFM BC to the con nector positi...

Страница 5: ...security Store the new service code in a save place Loosing of the service code leads to a factory reset which means sending the DFM BC to the factory with loosing of all setting parameters So be car...

Страница 6: ...Value according to the table Flow meter Type e Press OK to confirm the modification f The Output Value can be chosen from the Flow meter Type table or set a value of your choice Flow meter Type Input...

Страница 7: ...he 4 screws Put the upper part of the DFM System gently a side Be CAREFULL The upper part is connected to the base part with a flat cable 2 Look at the print on the base You will see a terminal block...

Страница 8: ...ting from the previous position press many times the down arrow until you reach the menu point Clock b On the line Date press OK Modify the date by using the down arrow or the up arrow Move from left...

Страница 9: ...own 7 Take the DFM BC If it is off press one of the 4 Keys on the front to reactivate it Go to the menu point Service Press OK and enter the Service Code Standard service code is 1111 8 Set the Auxili...

Страница 10: ...el system is purged according to engine manufacturer advice leak and bubble free If this is not the case please set the system in proper operating condition 1 Start the engine and let it run at min lo...

Страница 11: ...period The Menu structure has 3 branches User Mode Is intended for the daily user It informs him about the daily needed information Info Mode Is intended for the advanced user It shows you deeper info...

Страница 12: ...rrow or down arrow to the Info screen and press OK After you entered the Info Mode the 2 ESC key has always the same function it brings you back one step to the Info Mode 3 up arrow brings you to the...

Страница 13: ...ce the commission TRIP Engine consumption since the last reset Current Current engine consumption Supply Configuration SL K F Optimization value for best flow meter performance SL app Optimization val...

Страница 14: ...me Factory Data This screen shows you the firmware version and the serial number of the DFM BC which can will change over the time For Service People parameter setting Service Mode In this section we...

Страница 15: ...ser Reset AUX Move the bar over the line you would like to change parameters Press OK The changeable field will be highlighted for changing Make your changes and press OK to accept If there are securi...

Страница 16: ...et Current No function will be activated Op hours Reset of the total amount of working hours of the return line flow meter since commis sioning This value must be reset in case the flow meter was chan...

Страница 17: ...y is possible Config Log Entry Press OK to enter the Config log Read the stored Config Messages Config Log With the arrow and the arrow you can scroll through the messages Each message has a date and...

Страница 18: ...n Error Messages If an error has occurred and it has consequence for the following digital readouts Total or TRIP or the Consumption than the Board Computer DFM BC will show the following on the displ...

Страница 19: ...pply line flow meter has a flow rate Return line flow meter has a flow rate But the Supply line flow meter flow rate is smaller than Return Line flow meter flow rate Possible causes Leak on the supply...

Страница 20: ...tion For Service People parameter settings enter the sub section Return Configuration and change the RL app or the SL app What to do if there is a malfunction No Display on the Board Computer DFM BC 1...

Страница 21: ...used to feed the following flow meters DFM 8D DFM 20S DFM 25S or others Pin 2 Ground for the flow meter This connection is used as ground for the following flow meters DFM 8D DFM 20S DFM 25S and othe...

Страница 22: ...ow meters Pin number Flow meter 1 2 GND Connection for the supply line flow meter or for the flow meter for 3 direct consumption measurement Flow meter 2 8 GND Connection for the return line flow mete...

Страница 23: ...fferential consumption 18598 l Black Brown Yellow Green Red White DFM 8D DFM BC Battery DFM Board Computer Batt Batt 18598 l Supply Line DFM BC Battery Return Line Black Brown Yellow Green Black Brown...

Страница 24: ...al consumption 18598 l Supply Line DFM BC Battery Black Brown Yellow Green Red and White are not used DFM Board Computer Batt Batt VZP 4 8 supply line White not used VZP 4 8 return line White not used...

Страница 25: ...DFM Board Computer DFM BC Batterie Batt Batt Fuse max 1A or lower DFM BC to VZF A for differential consumption DFM BC to VZF A II for differential consumption Supply line VZF A Return line VZF A Flee...

Страница 26: ...e C 20 80 20 80 20 80 Ambient temperature 2 C 40 125 40 125 40 125 Max filter mesh size mm 0 100 0 100 0 250 Protection class according to IEC 60529 IP 66 IP 66 IP 66 Hydraulic connections M14x1 5mm G...

Страница 27: ...lses per liter Temperature Ambient 10 70 C Protection class IP 54 according to IEC 60529 Electrical connection Power supply with cable 2 x 0 75 mm2 2 m supplied Cable outer diameter 5 0 mm Dimensions...

Страница 28: ...uthorities METAS and PTB The electronic products have to pass an individual quality test Therefore Aquametro Oil Marine AG guarantees for the Product Quality perfect material machining and function of...

Отзывы: