16
CONTOIL
®
DFM
Filter
delay:
enter a value from 1 to 99. This allows you to decide how strong the stabilizing of the
current consumption should be. Use this feature if the current consumption is jumping from low to
high
values.
Switch between 2 modes:
- dark background and bright text (Yes)
- bright background und dark text (No)
Supply Line (Total, TRIP, Current)
Move the bar over the line you would like to change parameters. Press OK. The changeable field will be highlighted for changing. Make
your changes and press OK to accept. If there are security questions, answer it with YES or NO.
Total: Reset of the total amount of the fuel which has passed through the supply line since commis-
sioning. This value should only be reset in case the flow meter was changed.
TRIP: Reset of the total amount of the fuel which has passed through the supply line since the last reset.
Current: No function will be activated.
Op. hours: Reset of the total amount of working hours of the supply line flow meter since commis-
sioning. This value must be reset in case the flow meter was changed..
Return Line (Total, TRIP, Current)
Move the bar over the line you would like to change parameters. Press OK. The changeable field will be highlighted for changing. Make
your changes and press OK to accept. If there are security questions, answer it with YES or NO.
Total: Reset the total amount of the fuel which has passed through the return line since commission-
ing. This value must be reset in case the flow meter was changed.
TRIP: Reset the total amount of the fuel which has passed through the return line since the last
reset.
Current: No function will be activated.
Op. hours: Reset of the total amount of working hours of the return line flow meter since commis-
sioning. This value must be reset in case the flow meter was changed.
Consumption Overview (Total, TRIP, Consumption)
The only thing you can change is the TRIP. Press OK to reset this value. This action will be followed
by security questions. Answer the question with YES or NO until the value will be changed.
The
Current shows you the calculated difference between the supply line and the return line, the
Total shows you the total consumption.
Supply Configuration (SL KF, SL app, Qmax)
Move the bar over the line you would like to change parameters. Press OK. The changeable field will be highlighted for changing. Make
your changes and press OK to accept. If there are security questions, answer it with YES or NO.
SL KF: Enter the SL K’F-value which you will find on the type plate of the flow meter. This value is to
optimize the flow meter performance.
SL app: Put in a % value for a possible application correction. For more information go to the section
“High
Performance
Results”
Qmax: This value shows the peak flow rate ever measured in the return line.
Return Configuration (RL KF, RL app, Qmax)
Move the bar over the line you would like to change parameters. Press OK. The changeable field will be highlighted for changing. Make
your changes and press OK to accept. If there are security questions, answer it with YES or NO.
RL cal: Enter the RL K’F-value which you will find on the type plate of the flow meter. This value is to
optimize
the
flow
meter
performance.
RL app: Put in a % value for a possible application correction. For more information go to the section
“High
Performance
Results”
Qmax: This value shows the peak flow rate ever measured in the return line.