12
CONTOIL
®
DFM
Consumption
This picture shows the current consumption of the Engine in l/h.
Previous screen
Next screen
The next two screens (Info Mode and Service Mode) are explained in the section
for Managers
and
for Service People.
Display Test
Press OK
to start the Display test.
Previous screen
Next screen
This will start the Display test. The screen will switch from a black screen to a blank screen and back. At the end of the test it will go to
the “Total screen”.
During the switching from black to blank, have a look at the surface for missing pixels (points). If you saw missing pixel, then the display
must be changed (use the Repair Form). If you do not have one, contact your local dealer.
For Managers ... more and deeper information (Info Mode)
Take a few minutes to read first the section
User Mode
. It is the base for the next section.
In the “Info Mode” you have all the relevant DFM-System information at a glance.
1.
1.
From
the
User Mode
go with the
up arrow or
down arrow to the Info screen and press OK.
After you entered the “Info Mode”, the
2.
ESC
key has always the same function: it brings you back one step (to the Info Mode).
3.
up arrow
brings you to the previous screen or to the line above
4.
down arrow
brings you to the next screen or to the next line
In the following sections, the
ESC
key,
up arrow
and the
down arrow
will no further be described.
Entering the Info Mode
Press OK to enter the Info mode
Be aware: NO changes are possible in the Info Mode. This is just intended for Information.
Configuration (Information about Input / Output Value, RL flow meter, User Reset)
Input: v
alue of the incoming signal in ml/pulse
Output:
value of the outgoing signal. This value shall be higher than the “Input Value”
RL sensor
(flow meter): is a Return Line flow meter installed? (Yes / No)
User reset:
it is allowed for the user to do a reset? (Yes / No)
Aux:
communication line to an external device (e.g, Fleet Manager, GPS-Tracking system)
Filter delay:
shows the Filter delay value used to stabilize the current consumption (value between
1
and
99).
Be aware:
the Return Line flow meter
must
be the same like the Supply Line flow meter