Emergency action
In case of water treatment or a technical issue, the drum filter can be briefly halted.
Emergency action on a Gravity set-up
1) Switch off power supply to the Controller Box
2) Remove the 2 red caps in the separation wall (see legend, number 10)
3) Disconnect the circulation pump from the Controller Box and insert it into a separate
socket.
Emergency action on a pump-fed system
Disconnect the power supply and close all piping off.
Slip coupling torque 65Nm
The drive shaft is fitted with a slip coupling. When the drum is blocked for any reason, it is
activated.
Setting the torque
1) Remove the motor cover.
2) Place torque wrench on M10 nut which is on the shaft.
3) Hold the drum in position while setting the torque to 65Nm.
If this unclear or you need help please contact your dealer.