AQUA
FOG
9
XE 360
*Grounded and suitable for outdoor use.
Wiring the Oscillator
EXTENSION CORD SPECIFICATIONS*
FOR SINGLE FAN USE ONLY • (AWG - American Wire Gauge)
Voltage 25 to 50 ft. 50 to 100 ft.
115 16 AWG 14 AWG
P
OWER
C
ONNECTION
GROUND FAULT RECEPTACLE IS RECOMMENDED AND MAY BE
REQUIRED BY LOCAL AND/OR NATIONAL CODE.
PROPERLY
GROUND ALL
CONNECTIONS
Remove the black plug from the the top of the
motor's junction box. Install the oscillator power
cord and connector. This cord is pre-measured to
the appropriate length. DO NOT SHORTEN.
Remove the motor junction box cover. Strip the
ends of the oscillator power cord wires. Using the
wire nuts provided, connect the oscillator cord
wires and GT 500-HS motor wires as shown in the
appropriate wiring schematic. (See Page 17)
NOTE:
GT 500-HS motors are dual voltage and
can operate either on high or low voltage.
For connection changes, refer to the electrical
schematic located on the motor.
ALL WIRING AND ELECTRICAL
CONNECTIONS MUST BE
PERFORMED BY A QUALIFIED ELECTRICIAN.
WARNING
Oscillator
WARNING
Leave
Slack
On/Off
Switch
www.JigglyGreenhouse.com | (800) 878-7829 | [email protected]