10
Turn on the water supply, let the tank fill, and then turn on the fan motor. Listen for any possible
abnormalities, such as the blades rubbing against the venturi and make adjustments if necessary.
If no problems are detected, slowly open the flow control valve until the desired fogging output is
achieved.
If using an oscillator
, check the rotational movement and be SURE THE POWER CORD HAS ENOUGH
SLACK. If there is not enough, try re-mounting the GT 500-HS with the oscillator power cord falling
in line with its motor.
The volume of fog can be
regulated by adjusting the Flow
Control Ball Valve.
Particle size is smaller at lower
outputs, so it is better to operate
the fan at a lower output for a
longer period of time.
O
PERATION
BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT OF THE
ROTATION PATH OF THE FAN BLADES. HIGH-SPEED WARNING. KEEP HANDS
CLEAR! MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH.
LISTEN FOR UNUSUAL NOISE OR VIBRATION.
CAUTION
BUMP START GT 500-HS and check for proper fan blade rotation (clockwise if looking at
front of unit). If incorrect, find rotation connection changes on the motor's electrical schematic.
GT 500-HS
Operational Controls
NOTICE
GT 500-HS CANNOT BE OPERATED DRY
DANGER
Water
Supply
Line
Tank
Access Lid
Power
Supply
Line
Flow Control
Ball Valve
(In Closed Positon)
Feed Line
ON/OFF
Electrical
Switch Box