background image

3

9.     Keep fingers away from a running unit; 

        fast moving and hot parts will cause injury 

        and/or burns.
10.  If the equipment starts to vibrate abnormally, 

        STOP the motor and check immediately for 

        the cause. Vibration is generally an indication 
        of trouble.

Fogging Precautions

DANGER

A motionless atomizer may 

appear safe, but its blade 

could suddenly begin high-

speed rotation without 

warning as a result of 

control programming.

When a GT 500-HS is automated by controls, 

warning signs should be posted near the high-

speed equipment.

Disconnect and lock out power source to inspect 

or service the unit.

G

ENERAL

 S

AFETY

Since the GT 500-HS uses high-speed components 

to atomize liquids, the following safety precautions 

must be observed at all times:

1.  Read all manuals included 

     with this product. Be familiar 

     with the product and controls.

2.  Follow United States  

 

     Environmental Protection Agency (EPA)    

     guidelines and regulations when fogging   

     pesticide or chemical solutions.

3.  Follow all local electrical and safety codes 

     as well as the United States National  

 

     Electrical Codes (NEC) and Occupational  Safety  

     and Health Act (OSHA).

4.  Only persons well acquainted with these 

     rules of safe operation should be allowed to 

     use the atomizer.

5.  Keep visitors away and NEVER allow children in 

     the work area.

6.  Before each use, inspect blade assembly 

     and electrical components for signs of damage, 

     deterioration, weakness or leakage. Repair or 

     replace defective items before using.

7.  Check all fasteners at frequent intervals for 

     proper tightness.

MOTORS, ELECTRICAL EQUIPMENT AND 

CONTROLS CAN CAUSE ELECTRICAL 

ARCS THAT WILL IGNITE FLAMMABLE 

LIQUID OR GAS. NEVER OPERATE OR 

REPAIR IN OR NEAR FLAMMABLE LIQUID OR GAS. 

NEVER STORE FLAMMABLE LIQUIDS OR GASES IN THE 

VICINITY OF THE ATOMIZER.

DO NOT ATOMIZE

FLAMMABLE MATERIALS.

1.     Humidity and cold air are

        two common asthma triggers.    

 

        Asthmatic people working  

 

 

        with this equipment need to

        be made aware of the risk.
2.     When atomizing toxic chemicals, follow  the  

        instructions provided by the chemical    

        manufacturer.

NEVER OPERATE THE

GT 500-HS WITHOUT THE 

SAFETY GUARD IN PLACE IF THE UNIT IS LOWER THAN 

SEVEN FEET ABOVE WORKING HEIGHT.

WARNING

WARNING

DANGER

HIGH-SPEED ROTATION

www.JigglyGreenhouse.com  |  (800) 878-7829  |  [email protected]

Содержание GT 500-HS

Страница 1: ...240V 50Hz Read Understand Retain for Future Reference GT 500 HS ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL UL and CSA Electrical Components NOTICE GT www JigglyGreenhouse com...

Страница 2: ...ting from misuse Safety Guidelines This manual contains very important information This information will help ensure SAFETY and PREVENT EQUIPMENT PROBLEMS Use these symbols to understand safety guidel...

Страница 3: ...ited States National Electrical Codes NEC and Occupational Safety and Health Act OSHA 4 Only persons well acquainted with these rules of safe operation should be allowed to use the atomizer 5 Keep vis...

Страница 4: ...ncentrate into the fresh water leading to the GT 500 HS Atomized Product Atomized Water or Chemical Solution Shut Off Valve Captured rainwater or pre mixed chemical solution located above GT 500 HS A...

Страница 5: ...the structure If there is ventilation mount the fan at the intake end of the structure Generally no oscillation is necessary unless the width of the structure is greater than 20 The best location for...

Страница 6: ...part All fans should be equipped with oscillation sweeping 360 Large Structures Closed or Minimum Ventilation In closed structures with little to no ventilation propel fog the length of the structure...

Страница 7: ...AUSE INJURY OR PROPERTY DAMAGE WARNING Lock Washer Finish Nut Nylon Lock Nut Hanger Nylon Lock Nut Finish Nut Lock Washer Flat Washer 5 16 18 Bolt Package Hanger 2 1 4 20 Bolt Nylon Lock Nut Lock Wash...

Страница 8: ...lot NOTE Use both sides of the M to access all four pivot angles Pivot Locking System Pivot Lock Motor s power cord Water line Wire tie Plug into a Control Panel or Plug into 60Hz electrical outlet UT...

Страница 9: ...his cord is pre measured to the appropriate length DO NOT SHORTEN Remove the motor junction box cover Strip the ends of the oscillator power cord wires Using the wire nuts provided connect the oscilla...

Страница 10: ...ze is smaller at lower outputs so it is better to operate the fan at a lower output for a longer period of time OPERATION BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT OF THE ROTATION PATH OF THE F...

Страница 11: ...may not be pointing properly into the reservoir behind the blade assembly The feed tube should be aimed slightly downward into the slot area between the motor shaft and the stainless steel plate rear...

Страница 12: ...nd remove mineral deposits and or calcium B If the vibration seems to be coming from the motor first check that the motor mounting hardware is securely tightened If hardware is secure remove the blade...

Страница 13: ...y To Switch Box Lower Feed Tubing Sump Wall Internal Pump Parts 539 540 126 154 400 089 541 86 85 109 110 400 041 84 45 45 84 507 385 65 lg ID 65 lg ID 542 559 400 012 35 543 554 42 W 2 547 548 565 54...

Страница 14: ...125 Oscillator s power supply port 154 58 32 514 500 658 42 660 57 58 Hanger Options U Bolts Hanger Bolt 395 116 518 514 13 500 USA USA 521 532 400 019 519 523 522 35 400 406 407 512 513 400 047 510...

Страница 15: ...4 barb 1 406 Nylon rivet 6 407 Rivet washer 6 481 1 2 black hex plug 2 500 SST Hanger 1 502 Housing 1 506 Safety guard 1 507 115V Power cord for 60 50Hz models 1 510 Blade set screw 1 511 Blade tip se...

Страница 16: ...8 bronze bearing 2 135 115 volt 60 Hz motor 1 136 220 240 volt 50 60 Hz motor 1 138 3 32 x 3 4 cotter pin SST 1 139 3 8 spacer 2 140 Thrust bearing 1 142 10 tooth brass gear 1 144 Upper gear stop 1 14...

Страница 17: ...481 and using a garden hose thoroughly flush tank and pump of any sediment 3 Main Motor The main motor is a permanently lubricated motor but occasionally applying some spray oil to external rusty area...

Страница 18: ...from direct or indirect misuse negligence accident lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTE...

Отзывы: