17
M
AINTENANCE
DISCONNECT AND LOCK OUT POWER SOURCE
BEFORE SERVICING
WARNING
E
LECTRICAL
S
CHEMATICS
115V
1
Ph
60
Hz
(USA)
Pump
Tgl Switch
mtr
115V
240V
1
Ph
50
Hz
(Foreign)
Note: All green wires
go to ground
Denotes Line Connection
Denotes Wire Nut Termination
Electrical Schematic Code Designation
1. Inspect Blade Assembly
Clean the the exterior of the blades about
once a year or whenever a film of calcium or
mineral deposits is visible. While cleaning,
inspect for irregularities or hairline cracks and
replace as necessary.
2. Flush Out Tank
The tank should be rinsed regularly, especially
if using chemicals. Remove drain plug
(Part #481) and, using a garden hose,
thoroughly flush tank and pump of any
sediment.
3. Main Motor
The main motor is a permanently lubricated
motor, but occasionally applying some spray oil
to external rusty areas of the motor's body can
help extend the motor's life.
5. Storage
Protect your Aquafog from winter damage.
Expansion due to freezing can burst fittings,
solenoids and flowmeters. If storing unit in below
freezing temperatures, be sure all fluid is drained
from the unit. Damage due to freezing is not
covered under warranty.
SPST
TGS
On
Black
White
Off
115 VAC
LINE
N
1, 3, 8
mtr
FAN
2, 4, 5
115V
Oscillator
mtr
115V
White
Blue
Pump
Tgl Switch
mtr
230V
DPST
TGS
On
Brown
Blue
Off
240 VAC
LINE
1
mtr
FAN
4, 5
240V
Oscillator
mtr
240V
Yellow
Blue
DPST
TGS
Off
On
2, 3, 8
N