Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
53/72
Chose the Data Input Mode
dIn
of the Dosing Cycle Operation mode: to enter and exit the submenu, use
the
Enter
key, to browse through the “
tIn/ G.nC
” entries use
▲
and
▼. This section of the Menu will not be
displayed if the Relay mode has been selected from the previous
rEL
entry;
Set the duration of the Delay Phase for the programmable cyclic mode,
dlt
, within a range from 0
(deactivated) to 999 seconds: to enter and exit the submenu, use the
Enter
key, to browse through the
values use
▲
and
▼. This section of the Menu wil
l not be displayed if the Relay mode, has been selected
from the previous
rEL
entry;
Set the duration of the dosing Phase for the programmable cyclic mode,
do.t
, within a range of 1-99
minutes. To enter and exit the submenu, use the
Enter
key, and browse through the values with
▲
and
▼.
This section of the Menu will be displayed if the Relay operating mode,
rEL
, has not been selected, and the
data input mode is equal to
tIn
;
Set the amount of product to be dosed in g/cu. m. of water for the programmable cyclic mode,
G.nC
, within a
range of 0-99.9/ 100-999. To enter and exit the submenu, use the
Enter
key, and browse through the values
with
▲
and
▼. This section of the Menu will be displayed if the Relay operating mode,
rEL
, has not been
selected, and the data input mode is equal to
G.nC
;
Set the density of the product to be dosed,
dEn
, for the programmable cyclic mode, expressed as the
difference from the reference value of 1000 g/l, within a range of -50
÷
500, i.e. from 950 g/l to 1500 g/l: To
enter and exit the submenu, use the
Enter
key, to browse through the value use the keys
▲
and
▼; this
entry of the Menu will be displayed in case the Relay mode has not been selected through
rEL
, and the data
input mode is equal to
G.nC
;
Set the capacity of the pool in cu. m.
P.nc
, within a range of 1-999. To enter and exit the submenu, use the
Enter
key, and browse through the values with
▲
and
▼. This section of the Menu will be displayed if the
Relay operating mode,
rEL
, has not been selected, and the data input mode is equal to
G.nC
;
Set the duration of the Block Phase for the programmable Cyclic Mode,
bL.t
, within a range of 0
(deactivated) - 99 minutes. To enter and exit the submenu, use the
Enter
key, and browse through the
values with
▲
and
▼. This section of the Menu will be displayed if the Relay operating mode,
rEL
, has not
been selected;
Select if the cyclic programmable mode must be
Repeat
(see Operation section, Chap. 3.1)
r.St
: to enter
and exit the submenu, use the
Enter
key, to browse through the values use
▲
and
▼. This section of the
Menu will not be displayed if the Relay mode,
rEL
has been selected;
Set the stabilization time of the inhibiting signal,
Stb
, coming from the swimming pool recirculation pump,
within a range of 1-999 seconds: to enter and exit the submenu, use
Enter
, to scroll through the values use
the ▲ and ▼ keys;
Set the time of the pump maintenance alarm,
O.F.d
, from 0 (disabled) to 999 hours, based on the following
format:
-
h.mm
up to 9 h and 59 m
-
hh.m
up to 99 h and 59 m (minutes expressed in tens)
-
hhh
up to 999 h
To enter and exit the submenu use
Enter
and increase/decrease the value with the
▲
and
▼ keys;
Access the
In.t
inhibiting signal recognition window: to enter and exit the submenu use
Enter
. The display
will show the status identified by the pump for the input signal:
Steady "HI"
: enabling signal identified as active;
Steady "Lo"
: enabling signal identified as not active;
Flashing “HI”:
enabling signal identified as active, but slightly above the identification voltage threshold;
Flashing "Lo":
enabling signal identified as not active, but slightly below the identification voltage threshold;
If the status displayed does not correspond to the actual status of the signal or if the status displayed is
flashing, just scroll with the
▲
and
▼ keys to change the threshold, namely:
Status of the non-active signal (recirculation pump OFF):
if the signal is identified as active (steady or flashing
HI
) or not active but near the threshold (flashing
Lo
),
press ▼ to reduce the threshold voltage until a steady “
Lo
” is displayed;
if the signal is permanently identified as not active (steady
Lo
), conduct a check when the signal is
activated;