Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
47/72
To browse through the Menus refer to
- Menu Map.
Initial Menu
The first entry of the Initial menu displays one of the following pages, depending on the status of the switch:
(*)
(*)Value of the countdown expressed in seconds or minutes, displayed alternately to “rIt”, “doS”, “bLC” or “Stb”: if
the value is in minutes, it will be obtained by the speed of decrease of the value itself;
In case a time in seconds higher than 900 (15 minutes) is selected, the value will be displayed in
minutes
noS (Signal not active):
displayed if the inhibiting signal, which is linked to the pool water recirculation pump, is
not active;
Stb (Signal in Stabilization):
blinking value displayed if the inhibiting signal, which is linked to the pool water
circulation pump, is active but waiting to be stabilized;
dL.t (Delay Phase):
displayed during the programmed Delay (Dosing Cycle functioning), alternately to the
countdown values expressed in minutes or seconds;
doS (Dosing Phase):
displayed during the dosing of the pump (Dosing Cycle functioning), alternately to the
countdown values expressed in minutes or seconds;
bLC (Block Phase):
displayed during the pump's block phase of the Dosing Cycle while waiting for the following
dosing cycle to start, alternately to the countdown value expressed in minutes or seconds;
End (End of the Dosing Cycle):
displayed in Dosing Cycle operation after the Block phase, in case the Repeat
mode is active but the inhibitory signal is low; or in case the no Repeat mode is active and the inhibitory signal has
not had an inactive-active transition
(see Fig. 10)
rEL (Relay Mode):
displayed in Relay mode, when the start-up and switching-off phases of the pumps are directly
controlled from the recirculation pump;
By pushing
F
from the initial page, it is possible to browse through the other sections of the Menu and to display,
depending on the modes set:
Timed dosing cycle mode
set value of dosing time
do.t
, from 1 to 99 minutes;
Quantity dosing cycle mode
the value of product quantity
G.nC
set in grams per cu. m. of water, within a range from 0.0 to 99.9 with
decimal precision, and from 100 to 999;
By pushing
F
key from the value of minutes or g/cu. m., you will be re-directed to the main section.
In Relay mode, no section will be displayed when pushing
F
.
From any entry of the Initial Menu you can go to the:
Programming Menu
by pressing
Enter
for 3 seconds;
User Menu
by pressing the
F
key for 3 seconds;
User Menu
The User Menu allows to set the main pump dosing parameters.