Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
50/72
Quantity dosing cycle USER MENU
Fig. 10 - Standard programming from Quantity Mode User Menu
3.3 ADVANCED PROGRAMMING
Here below are the various features of the
Programming Menu
in greater detail.
Every parameter that is changed in the pump programming is saved when you go back to the initial
display. If the pump power supply is disconnected before going to the stand-by display, programmed
data is lost.
3.3.1 Setting the Language
From the
LAn
entry you can choose between Italian
It
and English
En
via the
▲
▼ keys.
Use
Enter
to enter and
exit.
(Fig. 11)
Fig. 11 - Setting the Language
3.3.2 Displaying and Resetting Statistics
By browsing the Programming Menu with the
F
key after
OPt
, the
StA
will be displayed. From this section, you will
access the pump statistics Submenu.
These are the parameters saved during pump operation:
Number of activations of the
CIC
Inhibitory Signal, from 0 to 999999, with the following format:
-
0 - 999
: number of cycles from 0 to 999;
-
1.00 - 9.99
: number of cycles from 1000 to 9999;
-
10.0 - 99.9
: number of cycles from 10000 to 99999;
-
100. - 999.
: number of cycles from 100000 to 999999;