450-DE/DM Hydronic Heating System Installation Manual
Section 9: Electronic Controller Wiring
Connecting the 12 Volt-DC Power:
DO NOT
connect the 12 Volt-DC power to the Aqua-Hot if
the vehicle requires welding. Electrical welding will cause serious
damage to the diesel-burner controller.
The Aqua-Hot is designed to shut down in the event
that the DC voltage level drops too low to properly
operate, it is imperative that the proper wire gauge be
determined and utilized. Reference Appendix B for
proper wire-gauge sizing. Please note that under full-
load conditions, the Aqua-Hot can draw as much as 22
amps of DC current.
Be sure to protect against accidental shorting (i.e., chas-
sis shorting) by incorporating a 25-Amp rated in-line
fuse into the power wire at the battery location. Refer-
ence Figure 47.
1.
Run and connect two wires –– one red (+) wire and
one black (-) wire (power and ground), from the ve-
hicle’s battery to the Aqua-Hot’s electronic controller.
Reference Appendix A and Figure 47.
2.
Label the wires indicating whether they are a power or a
ground wire.
3.
Attach the VDC power wires onto the appropriate ter-
minal/battery connections on the electronic controller.
Reference Appendix A.
4.
Connect both power and ground wires
directly
to the
vehicle’s batteries.
Optional connection to the
house battery disconnect
In-line
Fuse
Positive/Power
Negative/Ground
NOTE:
Reference Appendix A
for specific electronic
controller wiring
details.
NOTE:
If the optional power connection is used, remove the jumper
plate from the two power terminals - “JP5” and “JP8”.
DO NOT activate the diesel-burner until the antifreeze and
water heating solution has been added to the boiler tank
and the heating system has been completely bled of air.
Operating the Aqua-Hot without the antifreeze and water
heating solution will cause serious damage to the Aqua-
Hot’s boiler tank.
Connecting the 120 Volt-AC Power:
1.
Route and insert three 120 VAC power source wires
into the AC terminal block through the AC wiring
port’s cable clamp fitting and into the proper terminal.
Reference Appendix A and Figure 46.
2.
Secure the wires into their terminals by tightening the
corresponding screw on the terminal block. Reference
Appendix A.
Figure 47
AC Wiring
Port
AC Terminal
Block
Figure 46
Содержание 450-DE Series
Страница 1: ...Installation Manual 2008 Aqua Hot Heating Systems Inc...
Страница 41: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Appendix A Wiring Diagram Appendix A...
Страница 42: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Page A 1 Appendix A Wiring Diagram...
Страница 43: ...Appendix B Appendix B Wire Gauge Information...
Страница 45: ...Appendix C Appendix C Electronic Controller Features...
Страница 48: ...Appendix D Appendix D Antifreeze Types...
Страница 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Страница 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...
Страница 55: ...15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 www aqua hot com...