— Page 9 —
© 2008 Aqua-Hot
®
450-DE/DM Hydronic Heating System Installation Manual
Installing the Expansion Tank:
Select a mounting location that allows for easy access
and clear visibility whenever the particular storage bay
door is open.
NOTE:
The top of the expansion tank should always be
mounted at least 4 inches higher than the highest point
on the Aqua-Hot. Reference Figure 12.
1.
Mount the expansion tank as illustrated in Figure 12.
2.
Connect and clamp the overflow tubing from the
expansion tank to the Aqua-Hot’s expansion tank con-
nection. Reference Figure 12.
Figure 12
NOTE:
Avoid any dips and bends in the overflow tubing from
the Aqua-Hot to the expansion tank as air can become
trapped in these dips and bends, preventing the expan-
sion of the heating solution from properly depositing
in the expansion tank.
3.
Drill a hole in the bay floor and connect (secure with a
clamp) a long enough piece of overflow tubing so that
it can be connected to the top of the expansion tank
and extend through the bay floor.
Fill to “Cold” level
mark with “GRAS”
approved 50/50
antifreeze/water
mixture.
Air-Release Valve
Expansion Tank
Connection
Expansion Tank
Mount top of expansion
tank at least 4 inches
higher than the Aqua-Hot.
Overflow Tubing
Section 1: Aqua-Hot Installation
Overflow tubing from
expansion tank to hole
drilled in motorhome floor.
Содержание 450-DE Series
Страница 1: ...Installation Manual 2008 Aqua Hot Heating Systems Inc...
Страница 41: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Appendix A Wiring Diagram Appendix A...
Страница 42: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Page A 1 Appendix A Wiring Diagram...
Страница 43: ...Appendix B Appendix B Wire Gauge Information...
Страница 45: ...Appendix C Appendix C Electronic Controller Features...
Страница 48: ...Appendix D Appendix D Antifreeze Types...
Страница 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Страница 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...
Страница 55: ...15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 www aqua hot com...