— Page 13 —
© 2008 Aqua-Hot
®
450-DE/DM Hydronic Heating System Installation Manual
Section 2: Hydronic Heating System
Wiring the Heat Exchangers:
1.
Run two 18-gauge wires, red for (+) and black for (-),
from each particular heating zone’s heat exchanger to
the electronic controller. Reference Figure 22.
2.
Label the wires indicating the heating zone they pertain
to (e.g., Living Room, Bathroom, Bedroom, etc.).
3.
Insert all heat exchanger wires into the appropriate ter-
minal/heating zone location on the electronic control-
ler. Reference Figure 21 and Appendix A.
4.
Wire all heat exchangers in a zone in-series. Reference
Figure 23 and Appendix A.
5.
Connect all electronic controller wires to the positive
and negative leads of the heat exchanger. Reference
Figure 22.
NOTE:
Tolerance
+/- .030
+ (Positive) Red Wires
To Aqua-Hot’s Terminal
Block
- (Ground) Black Wires
To a chassis ground source
Mounting Tab
3.63 in.
13.06 in.
6.44 in.
14.44 in.
Figure 22
Figure 21
Reset Button
(Secondary
Power Source)
12 Volt-DC Screw
Terminal
(Primary
Power Source)
12 Volt-DC Screw
Terminal
Ground Wire
Screw Terminal
Header
Terminal Strip/Plug
Pin Jumper
J4
J1
J3
J2
1
1
1
1
Electronic Controller Board
To Motorhome
From Hydronic Heating
System Wiring Harness
Wire
Loom
Wire
Loom
Wire
Loom
Wire
Loom
Содержание 450-DE Series
Страница 1: ...Installation Manual 2008 Aqua Hot Heating Systems Inc...
Страница 41: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Appendix A Wiring Diagram Appendix A...
Страница 42: ...2008 Aqua Hot 450 DE DM Hydronic Heating System Installation Manual Page A 1 Appendix A Wiring Diagram...
Страница 43: ...Appendix B Appendix B Wire Gauge Information...
Страница 45: ...Appendix C Appendix C Electronic Controller Features...
Страница 48: ...Appendix D Appendix D Antifreeze Types...
Страница 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Страница 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...
Страница 55: ...15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 www aqua hot com...