Defrost Cycle 

The heat pump pool heater has automatic defrost.  When the outdoor temperature drops below 40 

°

F, frost may start to form on the evaporator coil.  Frost buildup will be heaviest on humid days 

when the temperature is between 35 and 40

°

 F.  During the defrost cycle, the display will show 

“DEF” 

indicating the unit is defrosting. During this time the compressor is inactive. 

 

Internal Protection Analyzers 

The heater is equipped with internal devices to monitor and protect the integrity of the unit.  If an 
abnormal condition occurs, the device will interrupt the operation of the unit and may display the 
appropriate code on the control panel. 
 

 

LOW WATER FLOW:  Indicated by 

“HP” 

or

 “HP3” 

on the control panel.  The heater is 

designed to run efficiently above twenty (20) GPM.  If there is insufficient water flow, 
the unit will shut down, protecting the compressor.  The usual causes for these conditions 
are a dirty pool water filter, a restriction in the return line (i.e. skimmer), or improper 
valve positioning. 

 

NO WATER FLOW:  Indicated by 

“FLO”

 on the control panel.  When the filter pump is 

off, or if the water flow to the heater is interrupted during the heating mode, the internal 
water pressure switch will shut down the unit.  When normal water flow resumes, the 
heater will automatically restart itself.  

 

Other analyzer codes include:  

“LP”, “tSO”, “tSS” 

and

 “ESO”

 and “

ESS

”. 

 
The TROUBLESHOOTING CHECKLIST on page 9 goes into further detail on these analyzer 
codes. 

 
MAINTENANCE 

WARNING:  DISCONNECT ELECTRICAL POWER TO UNIT BEFORE STARTING ANY 
MAINTENANCE TO PREVENT SERIOUS INJURY FROM SHOCK. 
 

 
Protecting your Heater 

 

Keep your pool filter system clean and free of restrictions to ensure proper water flow. 

 

Check water chemistry regularly.  Misuse of chemicals will cause permanent damage to 
your heater and other pool equipment.  Manufacturers can void warranties for damage as 
a result of poor water quality. 

 

Free airflow is essential.  Keep the evaporator coil clean and free of weeds, leaves, glass 
clippings, dirt and other debris that will decrease the airflow.  Keep fences and shrubs 
away from air inlets (sides and back of heater). 

 

Frequent rinsing of the evaporator with fresh water will remove build up from its surface.  
Always spray the coil gently with a regular garden hose being careful not to bend 
aluminum fins. 

 

Regular cleaning of the cabinet will improve its appearance and extend the life of the 
finish. 

 
 

Содержание ACT-1100T5S ACT-1250T6S

Страница 1: ...ELECTRICAL CONNECTIONS 4 WIRING DIAGRAMS 5 ELECTRONIC CONTROL PANEL 6 OPERATING YOUR HEAT PUMP 6 START UP 7 MAINTENANCE 8 WINTERIZING 9 TROUBLESHOOTING 9 CALLING FOR SERVICE 10 SYSTEM OPERATING SPECS...

Страница 2: ...be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48 of clearance for air discharge top of u...

Страница 3: ...3 WATER FLOW CONNECTIONS...

Страница 4: ...ctly to the electrical enclosure will ensure a moisture tight seal extending the life of the heater 5 Attach grounding conductor to the ground lug provided inside the electrical enclosure labeled 6 In...

Страница 5: ...terminals labeled POOL SPA on the bottom right of the electronic control board In the case of a remote thermostat where the temperature will be regulated externally set the POOL MODE to the OFF positi...

Страница 6: ...croll to your desired temperature set point Once your new temperature set point has been reached release the UP or DOWN key Your new set point will be displayed for five seconds then revert back to th...

Страница 7: ...continuously for at least 24 hours or more depending on the following factors Temperature difference between actual water temperature and desired water temperature Size of pool Ambient air temperature...

Страница 8: ...water flow to the heater is interrupted during the heating mode the internal water pressure switch will shut down the unit When normal water flow resumes the heater will automatically restart itself...

Страница 9: ...the heater to run Check to make sure the evaporator coil has enough clearance and that there are no restrictions to its airflow Certain ambient air conditions may cause the heater to go into defrost m...

Страница 10: ...sensor wiring or defective sensor DEF Heat pump in defrost cycle CALLING FOR SERVICE Visit www aquacomfort com click Service and complete the Service Request form Please eliminate any water flow prob...

Страница 11: ...arge Pressure psi Suction Pressure psi Superheat F ACT 750T4S 340 350 150 160 8 12 ACT 1100T5S 330 340 150 160 8 12 ACT 1250T6S 315 325 140 150 12 16 ACT 1500T7S 315 325 140 150 12 16 ACT 1750T7S 315...

Страница 12: ...ntenance and electrical service H Units sold outside the continental United States SERVICE PERFORMED WITHIN THE WARRANTY PERIOD must be approved by ACT PRIOR to service being performed and must be per...

Страница 13: ...____________________________________________________ City State _______________________________________________ Zip 4 _______________ Installation Date _________________Dealer ________________________...

Отзывы: