WIRING DIAGRAM
1.
Use copper conductors only
2.
Connect field wiring in grounded rain tight conduit, per rating plate.
3.
Connect bond wire to pool steel using # 8 solid copper wire or larger.
4.
All wiring must conform to National (N.E.C.) and local electrical codes.
INDICATES FACTORY WIRING
- - - - - - - - - - - -
INDICATES FIELD WIRING
REMOTE THERMOSTATS AND CONTROLLERS:
If a remote thermostat or any other control system is to be used to turn the heater on and off, a
normally open dry contact can be made at terminals labeled
POOL/SPA
on the bottom right of
the electronic control board. In the case of a remote thermostat where the temperature will be
regulated externally, set the POOL MODE to the OFF position and the SPA MODE to 104º F
(40º C). The heater will only run when the remote control calls for heating (circuit closed).
To Change Between Pool and Spa set points automatically:
This change can be done automatically as the water flow is either directed to the pool or spa.
The use of an external water pressure switch in the spa piping
IS
necessary. A two-wire control
circuit must be connected from the water pressure switch to terminals labeled
POOL/SPA
on the
electronic control board
.