SAFETY CONSIDERATIONS 
 

 

Qualified personnel should perform installation, maintenance and service. 

 

Make sure all field wiring conforms to the heater specifications and all national and local 
codes. 

 

Disconnect all power sources before performing any maintenance or service to the heater. 

 

 
INSPECTION 

Immediately upon receipt, inspect cartons and their contents for damage due to transit.   
Damage, if found, should be noted on delivery papers and a claim filed with the carrier.  Also, 
check unit data plate to make sure you have the proper model, before installing. 

 
GENERAL INFORMATION 

The information in this manual was prepared to assist in the proper installation, operation, 
maintenance and service of your new heat pump pool heater.  Please read the entire manual and 
follow all instructions.  Improper installation and use can result in damage to the heater, 
unsatisfactory operation, and may void the warranty.  Retain this manual for quick reference. 
 

INSTALLATION 

When selecting a location consider the following: 

 

Heater must be located outdoors. 

 

Minimum of 24” of clearance on access / service side of heater. 

 

Minimum of 18” of clearance on all three air intake sides of heater. 

 

Minimum of 48” of clearance for air discharge (top of unit). 

 

The heater should sit on a solid level surface sufficient above grade to prevent water from 
entering it, and allowing condensate to drain from base. 

 

The length of water piping and electric should be kept to a minimum to avoid capacity 
loss and decreased efficiency.  

  

WATER FLOW & CONNECTIONS 

Water connections are made at the front or rear of the heater.  Water in and out is labeled at the 
connections. Unions are supplied and are made to accept either 2” or 1 ½” rigid PVC pipe. The 
minimum flow rate is 20 GPM and the maximum flow rate is 70 GPM. 

NOTE:  Unions can be used for quick drainage of your heater and winterizing

 

 

Heater must be piped downstream from filter in the pool return line.

  

 

 

When all the plumbing connections are complete, and ample drying time is allowed, run 
the filter pump and check the entire system for water leaks. 

 

Make sure filter is clean and there are no obstructions in the filtering system. 

 

Proper water flow is essential to the performance of your heat pump.  

 

The minimum flow rate is 20 GPM. 

Содержание ACT-1100T5S ACT-1250T6S

Страница 1: ...ELECTRICAL CONNECTIONS 4 WIRING DIAGRAMS 5 ELECTRONIC CONTROL PANEL 6 OPERATING YOUR HEAT PUMP 6 START UP 7 MAINTENANCE 8 WINTERIZING 9 TROUBLESHOOTING 9 CALLING FOR SERVICE 10 SYSTEM OPERATING SPECS...

Страница 2: ...be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48 of clearance for air discharge top of u...

Страница 3: ...3 WATER FLOW CONNECTIONS...

Страница 4: ...ctly to the electrical enclosure will ensure a moisture tight seal extending the life of the heater 5 Attach grounding conductor to the ground lug provided inside the electrical enclosure labeled 6 In...

Страница 5: ...terminals labeled POOL SPA on the bottom right of the electronic control board In the case of a remote thermostat where the temperature will be regulated externally set the POOL MODE to the OFF positi...

Страница 6: ...croll to your desired temperature set point Once your new temperature set point has been reached release the UP or DOWN key Your new set point will be displayed for five seconds then revert back to th...

Страница 7: ...continuously for at least 24 hours or more depending on the following factors Temperature difference between actual water temperature and desired water temperature Size of pool Ambient air temperature...

Страница 8: ...water flow to the heater is interrupted during the heating mode the internal water pressure switch will shut down the unit When normal water flow resumes the heater will automatically restart itself...

Страница 9: ...the heater to run Check to make sure the evaporator coil has enough clearance and that there are no restrictions to its airflow Certain ambient air conditions may cause the heater to go into defrost m...

Страница 10: ...sensor wiring or defective sensor DEF Heat pump in defrost cycle CALLING FOR SERVICE Visit www aquacomfort com click Service and complete the Service Request form Please eliminate any water flow prob...

Страница 11: ...arge Pressure psi Suction Pressure psi Superheat F ACT 750T4S 340 350 150 160 8 12 ACT 1100T5S 330 340 150 160 8 12 ACT 1250T6S 315 325 140 150 12 16 ACT 1500T7S 315 325 140 150 12 16 ACT 1750T7S 315...

Страница 12: ...ntenance and electrical service H Units sold outside the continental United States SERVICE PERFORMED WITHIN THE WARRANTY PERIOD must be approved by ACT PRIOR to service being performed and must be per...

Страница 13: ...____________________________________________________ City State _______________________________________________ Zip 4 _______________ Installation Date _________________Dealer ________________________...

Отзывы: