background image

 

 

12

 
 

 

LIMITED WARRANTY

 

HEAT PUMP POOL HEATERS 

 

 
 
 
AQUACOMFORT TECHNOLOGIES, LLC. (ACT) warrants only to the original owner, the HEAT 
PUMP POOL HEATER to be free of defects in materials and workmanship for a limited ten (10) year 
term as follows:  One (1) year full parts and labor, years two (2) through ten (10) the compressor and heat 
exchanger (part only).  This warranty does not include transportation charges for equipment or component 
parts to or from the factory.  This warranty is valid only in the Continental U.S.  The labor for repair or 
replacement of defective parts will be provided by ACT subject to the conditions of this limited warranty. 

 
THE EFFECTIVE DATE OF WARRANTY

 is the date of installation, if properly documented, 

otherwise the date of manufacture plus three (3) months. 
 

THIS WARRANTY WILL NOT APPLY TO: 

 A) Malfunction or damage resulting from installation, 

operation, maintenance, voltage conditions, or service not in accordance with ACT specifications.  B) 
Malfunction or damage due to the failure to perform normal maintenance as outlined in the Owner’s 
Manual.  C) Malfunction or damage due to conditions not intended for original use of the unit.  D) 
Malfunction or damage due to negligence, abuse, freezing conditions, accident, or acts of God.  E) 
Malfunction or damage from plants or animals.  F) Malfunction or damage from the attachment of 
accessories not authorized by ACT.  G) Unnecessary service calls due to erroneous operational reports, 
maintenance and electrical service.  H) Units sold outside the continental United States. 

 
SERVICE PERFORMED WITHIN THE WARRANTY PERIOD 

must be approved by ACT 

PRIOR

 

to service being performed, and must be performed by an authorized technician.  The warranty is void if 
the unit is repaired by anyone unauthorized by ACT.  Reimbursement for replacement parts or repair 
services that are not authorized or performed by ACT are not covered under this limited warranty. 
 

WARRANTY PARTS

 will be replaced or repaired at the discretion of ACT.  Shipping of warranty parts 

is not included.  Defective parts must be returned to ACT within the warranty period for validation.  ACT 
is not liable for the labor involved in the unauthorized repair, or replacement costs including parts and 
labor.  This warranty is in lieu of all other warranties, expressed or implied, written or oral.  The liability 
of ACT shall not exceed the cost of the repair or replacement of defective parts; ACT is not liable for 
damages of any sort whatsoever, including incidental and consequential.  There are no implied warranties 
of fitness for a particular purpose that apply to this product. 
 
Owner________________________________                      
Address_______________________________ 
City/St/Zip_____________________________                    
Installation Date_________________________         

  

Contractor_____________________________              
Address_______________________________                                        
City/St/Zip_____________________________ 
In-Ground Model #______________________ 
Serial #________________________________ 

 

 
  KEEP FOR YOUR RECORDS 
 DO NOT MAIL CERTIFICATE

 

 

AQUACOMFORT TECHNOLOGIES, LLC. 

Service Department 

P.O. BOX 669 

Sorrento, FL 32776-0669 

 

 

Содержание ACT-1100T5S ACT-1250T6S

Страница 1: ...ELECTRICAL CONNECTIONS 4 WIRING DIAGRAMS 5 ELECTRONIC CONTROL PANEL 6 OPERATING YOUR HEAT PUMP 6 START UP 7 MAINTENANCE 8 WINTERIZING 9 TROUBLESHOOTING 9 CALLING FOR SERVICE 10 SYSTEM OPERATING SPECS...

Страница 2: ...be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48 of clearance for air discharge top of u...

Страница 3: ...3 WATER FLOW CONNECTIONS...

Страница 4: ...ctly to the electrical enclosure will ensure a moisture tight seal extending the life of the heater 5 Attach grounding conductor to the ground lug provided inside the electrical enclosure labeled 6 In...

Страница 5: ...terminals labeled POOL SPA on the bottom right of the electronic control board In the case of a remote thermostat where the temperature will be regulated externally set the POOL MODE to the OFF positi...

Страница 6: ...croll to your desired temperature set point Once your new temperature set point has been reached release the UP or DOWN key Your new set point will be displayed for five seconds then revert back to th...

Страница 7: ...continuously for at least 24 hours or more depending on the following factors Temperature difference between actual water temperature and desired water temperature Size of pool Ambient air temperature...

Страница 8: ...water flow to the heater is interrupted during the heating mode the internal water pressure switch will shut down the unit When normal water flow resumes the heater will automatically restart itself...

Страница 9: ...the heater to run Check to make sure the evaporator coil has enough clearance and that there are no restrictions to its airflow Certain ambient air conditions may cause the heater to go into defrost m...

Страница 10: ...sensor wiring or defective sensor DEF Heat pump in defrost cycle CALLING FOR SERVICE Visit www aquacomfort com click Service and complete the Service Request form Please eliminate any water flow prob...

Страница 11: ...arge Pressure psi Suction Pressure psi Superheat F ACT 750T4S 340 350 150 160 8 12 ACT 1100T5S 330 340 150 160 8 12 ACT 1250T6S 315 325 140 150 12 16 ACT 1500T7S 315 325 140 150 12 16 ACT 1750T7S 315...

Страница 12: ...ntenance and electrical service H Units sold outside the continental United States SERVICE PERFORMED WITHIN THE WARRANTY PERIOD must be approved by ACT PRIOR to service being performed and must be per...

Страница 13: ...____________________________________________________ City State _______________________________________________ Zip 4 _______________ Installation Date _________________Dealer ________________________...

Отзывы: