40
Overview
No. Designation
1
Bearing cover
2
Hexagon key holder
3
Cover nuts
4
Locking ring
5
Agitator shaft
Procedure
This is how to deactivate the agitator:
Step
Description
Explanation
1
Open the bearing cover (1).
To do so, loosen the cover nuts (3) with
the hexagon key.
2
Pull the locking ring (4) off of the agitator
shaft (5) and put it aside.
3
Push in the agitator shaft.
4
With a rotating movement, push the
female pin (6) through the guide duct (7)
on the motor side and turn clockwise up
to the stop.
Result:
5
Close the bearing cover (1).