19
-
SWING APRICODE 230
CONTROL UNIT
English
Component layout and connections
fi g. 1 -
Programming buttons
:
YELLOW
ESC to exit the current phase and show the connections on the display (and can be used before self-
teaching to operate motor 1 during manned functioning)
BLUE
SCROLL to scroll through the options available (and can be used before self-teach process to drive motor
2 when manned)
RED
OK, use this to open programming and to con
fi
rm the option displayed.
WARNING! The N.C. contacts must have a jumper inserted between the contact and the earth (terminal
10 or 12) when they are not in use. If you do not do this the automation WILL NOT work.
DL1
8 8 8 8
1
3
6 7
10 11 12
2
4
5
8 9
13
F3
F2
F1
4
2
3
1
4
2
3
1
J10
J9
J15
J4
M1
CN1
CN2
J1
DS1 DS2 DS3 DS4
FS1
FS2
JRX
FS3
FS4
FS5
J12
CN3
J16
L N
J11
1 2
FS6
FS7
J13
J14
+
-
-
+
-
-
PH
N
}
GND
M2
M1
}
encoder 1
encoder 2
12VAC 15W max.
*
J16
photocell transmitting
when negative
(standard photocells)
or
to TST terminal
(REFLEX photoc. type)
not used
CAP
ACIT
OR M1
CLOSE OPEN COMMON
CAP
ACIT
OR M2
CLOSE OPEN COMMON
power supply
230V 50Hz
+6% -10%
PHASE
EAR
TH
NEUTRAL
LEGEND:
M1 = motor 1st wing opening or single wing
M2 = motor 2nd wing opening
RED GREEN RED
BLUE BLACK
YELLOW YELLOW
SECONDAR
Y
9-0-9 V
AC
PRIMAR
Y
230 V
AC
SECONDAR
Y
1
2 V
AC
= N.O. contact
= N.C. contact
TRANSFORMER
Electric lock
Electric lock
Flashing light control
Flashing light/AUX output power 24V
W
arning light control/
AUX output 24V 3W max
pedestrian opening ST
AR
T
(N.O.)
+ 24V
Accessories
Auxiliary safety device (N.C.)
Closing photocell (N.C.)
GND
ST
OP
(N.C.)
GND
ST
AR
T (N.O.)
* Aux. opening safety
device test
* Closing photocell test
YELLOW
(esc)
BLUE
(scroll)
RED