background image

 

SC 230

 

 
 

 
1.2 PED Function (or CH2) 

Press P2 button until PROG LED starts flashing; do not release P2 and wait for the flashing to become faster. Release P2 
button 
Enable the remote control key to be saved that you want to assign to the PED control within 10 seconds. Saving is completed 
when the PROG LED will flash for a longer time. 
Repeat the operation for each remote control to save. 

 
1.3 Deleting a single remote control 

Press P2 button until PROG LED starts flashing; do not release P2 and wait for the flashing to become faster; do not release 
P2 and wait for the flashing to become very fast. Release P2 button. 
Enable the key of the remote control that you want to delete within 10 seconds. Delete operation is completed when the 
PROG LED will flash for a longer time. 
Repeat the operation for each remote control to delete. 

 
1.4 Deleting all remote controls 

Switch-on the equipment by pressing the P2 button until the PROG LED starts flashing; do not release the button and wait for 
the flashing to stop. ALL remote controls are deleted when the PROG LED will flash for a longer time. 
 

1.5 Module Channel MCH2 function 

To enable dell'MCH2 command with the second radio control channel: 
press the P2 button until the PROG LED starts blinking; not release P2 and 
wait until the flash gets quicker; not release P2 and wait for the flashing 
become even faster; Release the P2 button. 
Continue with point 1.2 to learn the second channel of a TM4 associated all'MCH2 
 

1.6 DATA OUTPUT MCH2 

CN2 connector can be connected to the coupon MCH2. 
This board provides two NC and NO contacts that are activated for 1 sec at the reception of a 
pulse from a remote control button associated with MCH2 
If no remote control has been associated with MCH2 contacts are activated for about 1 sec in 
Following a SEQ command, PED, or OPEN. 
 

2) 

STROKE PROGRAMMING 

 

During saving, beside saving the slowing down spaces and the pedestrian opening stroke, the equipment will detect any 
supervised safety input PH1, PH2 or SAF. 
 

 

Press the save button P1 for at least 3 seconds 

 

 The PROG LED starts flashing: Release P1 button 

 

 Enable SEQ pulse: 

The gate closes at normal speed 

 

The gate searches the limit switch in closed position and stops. 

 

 After about 1 sec:

 The gate opens at normal speed 

 

 When you decide to start the slowing down stroke phase, enable

 SEQ

:

 

the gate slows down 

 

 The gate reaches the limit switch in open position and stops 

 

 After about 1 sec: 

 The gate closes at normal speed 

 

 When you decide to start the slowing down stroke phase, enable

 SEQ

:

 

the gate slows down 

 

 The gate reaches the limit switch in closed position and stops. 

 

 After about 1 sec: 

 The gate opens at normal speed 

 

 To fix the partial pedestrian opening, enable

 SEQ:

 the gate stops 

 

 

After about 1 sec:

  The gate closes until the limit switch in closed position is reached and stops. Wait for the PROG 

LED to turn off.

 

 

 

During stroke programming phase, if the stop time (TR1 trimmer DELAY) is set to 0 seconds, the pedestrian control will set to 
stop time of 1 second of TR2 DELAY which cannot be changed; while if strokes are learned with DELAY > than 1 second, the 
TR1 trimmer DELAY also changes the pedestrian function stop time. 
 

14 

Содержание 41626/001

Страница 1: ...e de vie du produit Afi n d viter des op rations incorrectes et de ne pas risquer des accidents s rieux lire attentivement ce manuel et respecter scrupuleusement les informations fournies Les instruc...

Страница 2: ...alide per la sicurezza nei cantieri Delimitare il cantiere per impedire il transito a persone non autorizzate e non lasciare incustodita la zona di lavoro Installazione collegamenti elettrici e regola...

Страница 3: ...adeguate misure correttive e applicare le segnalazioni previste dalle norme vigenti per individuare le zone pericolose Ogni installazione deve riportare in modo visibile l indicazione dei dati identif...

Страница 4: ...rtura Chiusura Apertura Eccetera 3 La Funzione cortesia abilita la chiusura dopo 5 secondi che le fotocellule hanno ricevuto un impulso indipendentemente dal tempo di lavoro 4 La funzione condominiale...

Страница 5: ...si luce spenta battenti chiusi M1 8 TST Se dip 9 ON Out Test sicurezze Se dip 9 OFF Out Lampeggiante a LED 7 MCL Avvolgimento Chiusura Motore 6 MOP Avvolgimento Apertura Motore 5 MCOM Comune Motore 4...

Страница 6: ...locca tempo pausa impostato e CHIUDE PASSO PASSO CON STOP Stesso comportamento della logica PASSO PASSO con la differenza che Nella fase di apertura dando un comando SEQ il cancella si blocca dando un...

Страница 7: ...connessa la schedina MCH2 Tale scheda fornisce due contatti NC e NO che vengono attivati per 1 sec alla ricezione di un impulso da un pulsante di telecomando associato a MCH2 Se nessun telecomando st...

Страница 8: ...olizione dello stesso Esse devono essere consegnate all utilizzatore e devono essere lette attentamente poich contengono importanti avvertimenti per l uso e la manutenzione Questa apparecchiatura deve...

Страница 9: ...e the working area unattended Installation electrical connections and adjustments must be carried out in a professional manner in compliance with the good manufacturing and workmanship regulations in...

Страница 10: ...ut a risk analysis and check that the system does not feature crushing or shearing points If necessary corrective measures must be implemented and signals required by current regulations must be appli...

Страница 11: ...ing Closing Opening Etc 3 The Courtesy function enables the closing 5 seconds after the photocells have received a pulse regardless of the working time 4 The condominium function disables the SEQ and...

Страница 12: ...ixed light swing gates NOT closed light off swing gates closed M1 8 TST If dip 9 ON Safety devices Test Out If dip 9 OFF LED flashing light Out 7 MCL Motor Closing Winding 6 MOP Motor Opening Winding...

Страница 13: ...STEP WITH STOP It works with the same logic of the STEP STEP but with the following differences During opening if a SEQ pulse is sent the gate will stop a further pulse will make the gate close Durin...

Страница 14: ...CH2 CN2 connector can be connected to the coupon MCH2 This board provides two NC and NO contacts that are activated for 1 sec at the reception of a pulse from a remote control button associated with M...

Страница 15: ...roduct throughout its life cycle up until decommissioning It should be stored in a accessible place ready for immediate reference The instructions and warnings must be given to the user and then read...

Страница 16: ...rigurosamente las normas nacionales de aplicaci n para la seguridad en las obras Delimitar la obra para impedir el tr nsito a personas no autorizadas y no dejar la zona de trabajo sin vigilancia La in...

Страница 17: ...i es necesario debe implementar las medidas de correcci n adecuadas y aplicar las se alizaciones previstas por las normas vigentes para identificar las zonas peligrosas Toda instalaci n debe exhibir d...

Страница 18: ...tc tera 3 La Funci n de cortes a habilita el cierre 5 segundos despu s de que las fotoc lulas hayan recibido un impulso independientemente del tiempo de trabajo 4 La funci n de condominio inhabilita l...

Страница 19: ...luz fija las hojas batientes NO est n cerradas luz apagada las hojas batientes est n cerradas M1 8 TST Si dip 9 es igual a ON Out Test seguridades Si dip 9 es igual a OFF Out parpadeante en LED 7 MCL...

Страница 20: ...TOP El mismo comportamiento de la l gica AUTOM TICA SUPER salvo que El mando SEQ en fase de cierre bloquea la cancela y un siguiente mando la ABRE El mando SEQ en fase de apertura bloquea la cancela d...

Страница 21: ...il secondo comando dell MCH2 col Canale del radiocomando Premere fino il pulsante P2 un quando il llev PROG comincia un lampeggiare no rilasciare P2 correo attendere che il pi veloce lampeggio divent...

Страница 22: ...a instalaci n el ctrica Se recuerda que las bater as no est n cubiertas por la garant a por ser consideradas material de consumo Se recomienda no desechar la bater a en el medio ambiente sino deposita...

Страница 23: ...al ajeno Aprimatic s r l declara que el dispositivo SC230 cumplen con los requisitos esenciales y otras exigencias relevantes de la Directiva 1999 5 EC Aprimatic srl Via Emilia 147 40064 Ozzano Emilia...

Страница 24: ...SC 230 Aprimatic srl Via Emilia 147 40064 Ozzano Emilia BO Italy Tel 39 051 6960711 Fax 39 051 6960722 info aprimatic it www aprimatic it 24...

Отзывы: