4-20 mA Option (loop powered):
NOTE 1:
The supply voltage must be sufficient to maintain a minimum of 9 VDC
after “dropping” voltage across the load resistance with the output at
20mA. Example: If RL = 250 ohm then “drop” is 0.02 Amps X 250 ohm
= 5 volts. Therefore power supply minimum is 5 V + 9 V = 14 V.
NOTE 2:
Completion of the earth ground (Pin F) is recommended for proper
circuit protection.
A
F
B
E
C
D
6 Pin Connector
Externally powered with 0-5 VDC or 0-2 VDC analog output:
A
F
B
E
C
D
6 Pin Connector
NOTE: C
ompletion of the earth ground (Pin F) is recommended for proper
circuit protection.