background image

Rev. A1, 3/10

PG5

5

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Содержание PG5

Страница 1: ...C T S G R O U P I N C Automation Products Group Inc APG Providing tailored solutions for measurement applications Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com E mail sales apgsensors com P...

Страница 2: ...G5 4 19 Menu Flow Chart 5 Changing the Mode Setting 6 Accessing Exiting the Setup Menu 7 Maximum Minimum Function 8 Units of Measure 9 Using Custom Units 10 Peak Hold Feature 11 Advanced Settings 12 1...

Страница 3: ...ny incidental or consequential damages losses or expenses directly or indirectly arising from the sale handling improper application or use of the goods or from any other cause relating thereto and AP...

Страница 4: ...o the gauge Secondary Function Cycles through the options in the setup menus S Button Primary Function Cycles between the current maximum and minimum pressure readings Secondary Function Used to accep...

Страница 5: ...Rev A1 3 10 PG5 5 Automation Products Group Inc APG Providing tailored solutions for measurement applications Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com...

Страница 6: ...de definitions below by using Z to change the value of the flashing digit and S to advance to the next digit Mode Definitions Mode 000 Full Access Provides access to all menu settings If no buttons ar...

Страница 7: ...e On Off button once to enter the main setup menu Step 2 Press Z to scroll through menu choices max min units peak hold advanced settings tare default and exit Exiting the Main Setup Menu Step 1 While...

Страница 8: ...Maximum pressure reading and the Minimum pressure reading The maximum and minimum readings will be stored until the gauge is powered down or the max min readings are reset Resetting the Max Min readin...

Страница 9: ...ter MPA megapascals FTH20 feet of water 60 F cmHG centimeters of mercury For gauges less than 120 psi PSI pounds per square inch bAR bar KPA kilopascals CUSTOM see Using Custom Units on next page mbAR...

Страница 10: ...ep 2 Press the On Off button once to enter the main setup menu Step 3 Press Z to cycle through the options until UNITS is displayed Step 4 Press S to access the Units setting options Step 5 Press Z to...

Страница 11: ...he Peak Hold feature is enabled a small box containing the words PEAK HOLD will be displayed in the upper left corner of the display Options Off or On Enabling the Peak Hold feature Step 1 Press the O...

Страница 12: ...matically powers down Options 2 MIN 4 MIN 8 MIN 16 MIN 32 MIN and OFF NOTE Selecting OFF disables the Auto Off feature the gauge will then remain powered indefinitely as long as there is sufficient vo...

Страница 13: ...n a gauge with 0 decimal place positions the display will increment in factors of 10 Options HI RES high resolution or LO RES low resolution Setting the Decimal Place feature Step 1 Press the On Off b...

Страница 14: ...y fluctuating readings Options SLOW 4x second MEdIUM 8x second FAST 16x second Setting the Sample Rate feature Step 1 Press the On Off button to enter the main setup menu Step 2 Press Z to cycle throu...

Страница 15: ...splay Bar Graph Step 1 Press the On Off button once to enter the main setup menu Step 2 Press Z to cycle through the options until AdVSET is displayed Step 3 Press S to access the Advanced Settings me...

Страница 16: ...order to adjust the Range feature If the reading is not within 5 of full scale NOAdJU No Adjustment will be displayed when trying to adjust the Range Adjusting the Full Scale Range Step 1 Ensure that...

Страница 17: ...e On Off button once to enter the main setup menu Step 2 Press Z to cycle through the options until AdVSET is displayed Step 3 Press S to access the Advanced Settings menu Step 4 Press Z to cycle thro...

Страница 18: ...Advanced Settings menu Step 6 Press Z to cycle through the setup options until AL CAL is displayed Step 7 Press S to access the Analog Low Calibration value A 5 digit number will appear with the firs...

Страница 19: ...is displayed Step 3 Press S to access the Tare setting options Step 4 Press Z to toggle between OFF and ON Step 5 Press S button to apply the displayed options and return to main setup menu NOTE 1 Wh...

Страница 20: ...Used to reset the gauge to the factory default settings Resetting the gauge to factory default settings Step 1 Press the On Off button once to enter the main setup menu Step 2 Press Z to cycle throug...

Страница 21: ...reo jack connector mate supplied on the back of the gauge The Tip connection is Power and the Center connection is Power Battery Replacement The battery is accessed by removing the single screw at the...

Страница 22: ...m of 9 VDC after dropping voltage across the load resistance with the output at 20mA Example If RL 250 ohm then drop is 0 02Amps X 250 ohm 5 volts Therefore power supply minimum is 5 V 9 V 14 V NOTE 2...

Страница 23: ...apgsensors com Battery powered with 0 2 VDC output option The 0 2 VDC signal is accessed through a stereo jack connection on the back of the gauge 0 2 VDC Output Tip Output Center Output Body No conn...

Страница 24: ...led and when using the Custom Multiplier in the Menu Locked Menu has peak hold enable disable with Select button not in Menu Menu has Units lbs kg Newton Can Zero Reading Z button Fixed External Power...

Страница 25: ...ivalent Added Decimal Place for Analog Output Set points Renamed SETUP to ADVSET in Menu When changing range the value then overwrites the default multiplier for field calibration PG5v107 hex created...

Страница 26: ...PG5 Rev A1 3 10 26 Automation Products Group Inc APG Providing tailored solutions for measurement applications Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com...

Страница 27: ...Rev A1 3 10 PG5 27 Automation Products Group Inc APG Providing tailored solutions for measurement applications Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com...

Страница 28: ...l copies of this manual ask for APG part number PN9003384 Rev A1 3 10 P R O D U C T S G R O U P I N C Automation Products Group Inc Tel 1 888 525 7300 1 435 753 7300 Fax 1 435 753 7490 e mail sales ap...