Decimal Place (dEC PL):
The reading can be set to display in High Resolution (HI RES) or Low
Resolution (LO RES) mode. Switching between high and low resolution will
shift the displayed reading by one decimal place position.
NOTE:
When Low Resolution mode is enabled on a gauge with 0 decimal place
positions, the display will increment in factors of 10.
Options: HI RES (high resolution) or LO RES (low resolution)
Setting the Decimal Place feature:
Step 1: Press the On/Off button to enter the main setup menu.
Step 2: Press (Z) to cycle through the menu options until AdVSET is
displayed.
Step 3: Press (S) to enter the Advanced Settings menu.
Step 4: Press (Z) to cycle through the options until dEC PL is displayed.
Step 5: Press (S) to access the Decimal Place setting options.
Step 6: Press (Z) to cycle between HI RES (high resolution) and LO RES (low
resolution).
Step 7: Press (S) to apply the displayed setting and return to main setup menu.