Rev. A, 6/15
MND
27
Resetting the MND to factory defaults
Simultaneously press and hold the Decrease/Power button and Enter button for
approximately 5 seconds. This will bring up the 3 digit operating mode number. Change
the mode number to 125 and press the enter button. This will reset all parameter values
to the following factory defaults:
Parameter Value
Units
Gallons
Auto-Off
65535 (disabled)
Decimal
Place
0
Digit Mask
Off
Digit Shift
0
Multiplier
1.000
Bar Graph 0
0
Bar Graph 100
10000
Over Load
99999 (max display value)
Battery Gauge Enable
No Battery
Battery Full
13.5 V
Battery Low
11.0 V
Analog Low Reading
0
Analog High Reading
99999
Analog Low Calibration
0
Analog High Calibration
16383
T1 Type
Off
T1
Reading 1000
T1
Window 500
T2 Type
Off
T2
Reading 1000
T2
Window 500
Baud
Rate 9600
Parity
None
Stop
Bits
1
C-Type
Master
Sensor
Address
1
Number of Sensors
1
Register Number
303
Function
4
Register Type
U32 (unsigned 32-bit)
Scan
Rate
000.5
seconds
Sensor Labels
Sen 1 - Sen 11
Percent Full
00000 (disabled)