MND
Rev. A, 6/15
20
WRITE
: allows the MND, operating in Master mode, to write a value to a specific
holding register of a specific sensor. When Write is selected, the MND will guide you
through the following steps:
Sensor Address:
set the address number of the target sensor.
Register Number:
set the register number you wish to change.
Register Type:
set the type of register being written (16-bit or 32-bit).
Register Value:
set the value you want to write to the selected register.
Write Yes/No:
select Yes to write the new register value and complete the
procedure, or No to cancel the write, and return to the Communications menu.
Write function example: changing the Empty Distance value (register 40407) to 2150
in sensor address number 5.
Sensor Address:
05
Register Number:
407
Register Type:
U16 (unsigned 16-bit).
Register Value:
02150
Write Yes/No:
select Yes by pressing Enter.
AdRCHG
(Address Change): allows the user to quickly change a sensor’s address
when the MND is operating as the Master device. Simply enter the current address of
sensor you wish to change (
NOW
), then enter the new address you wish to write to the
sensor (
NEW
).
www.
.com