Operator’s Manual

AUTOMATION

P R O D U C T S

GROUP, INC.

Automation Products Group, Inc.

MND

Modbus Network Display

DOC. 9003708

Rev. A, 6/15

www.

.com

[email protected]

1.800.561.8187

Содержание MND

Страница 1: ...Operator s Manual AUTOMATION P R O D U C T S GROUP INC Automation Products Group Inc MND Modbus Network Display DOC 9003708 Rev A 6 15 www com information itm com 1 800 561 8187...

Страница 2: ...hift 11 Multiplier 11 Bar Graph 11 Overload 12 Battery Indicator 12 Outputs 13 17 Analog Settings 13 Solid State Relay Settings 13 16 Switchable Power Source 17 Communications Settings 18 20 Sensor La...

Страница 3: ...le handling improper application or use of the goods or from any other cause relating thereto and APG s liability hereunder in any case is expressly limited to the repair or replacement at APG s optio...

Страница 4: ...Brown 24 VDC 24 VDC Relay Power 2 White RS 485 A RS 485 A RS 485 A 3 Blue DC Ground 4 20 mA Out DC Ground 4 Black RS 485 B RS 485 B RS 485 B No connection for MND s with internal batteries 2 1 4 3 5 C...

Страница 5: ...B RS 485 B 5 Grey N C N C N C Analog Out No connection for MND s with internal batteries 6 pin Tajimi No Output 4 20 mA Switchable Power 0 3 VDC A 24 VDC 24 VDC Relay Power 24 VDC B DC Ground 4 20 mA...

Страница 6: ...Grey Com 1 Com 1 2 6 Pink Com 2 NO NC 2 7 Blue DC Ground DC Ground 8 Red NO NC 2 Analog Out 1 2 3 4 5 6 7 8 8 C Cable 22 AWG 2 NO NC Relays 0 3 VDC 2 Relays 24 VDC Red Red DC Ground Black Black RS 485...

Страница 7: ...1 second to power on or off the MND Function within Setup Menu press to cycle downward through menu options or decrease mode setting values Enter Button Function in Operating Mode cycles between the...

Страница 8: ...ons are accessible including those that may not be applicable to all MND configurations 001 Locks access to all setup menus The Increase Button will scroll through sensor readings when the MND is conf...

Страница 9: ...4 SEN 8 SEN 9 SEN 7 LOERST EXIT EXIT EXIT SEN 10 MOdE bRTNES AVERGE SAM RT ENTR UNITS MAXMIN TEMP C TEMP F CU FT MCU FT CU M GALLON LITERS CU IN PCTFUL CUSTOM bARREL EXIT EXIT AL CAL AH CAL T1TYPE T2...

Страница 10: ...y display PCTFUL percent full for any reading being displayed in Percent Full mode see page 20 for more information ENTR Enter Button Function Selects the function of the ENTER button when in standard...

Страница 11: ...f the least significant digit s up to 3 places so that masked digit s will always display 0 and will not increment SHIFT Digit Shift allows the user to shift the reading to the right by dividing the r...

Страница 12: ...n 5 digit limit of the display bAT EN Battery Enabled allows the user to select either No Battery Internal Battery or RST Battery options The Internal Battery option is used to monitor the voltage of...

Страница 13: ...ation adjusts the high end of the analog output i e either 20mA or 3V Increasing decreasing the value will cause an increase decrease at the high end of the analog output T1TYPE T2TYPE Trip 1 2 Type d...

Страница 14: ...int the output will deactivate and remain in that state until the reading is less than the Trip Reading FAR The output will activate whenever the reading is greater than the Trip Reading NOTE for Norm...

Страница 15: ...s than the Trip Reading Trip Window H FAR Hysteresis Far The output will activate when the reading increases beyond the Trip Reading Trip Window and will remain active until the reading falls below th...

Страница 16: ...al in seconds NOTE when using the Timed Interval in conjunction with the Auto Off feature the MND will wake power on at each Interval and will remain powered on for the duration of the relay On Time r...

Страница 17: ...determines how long power is supplied to the sensor APG recom mends an On Time of 8 10 seconds to allow the sensor enough time to power up and get a reading The Auto Off setting determines how long t...

Страница 18: ...s the master device SETUP sets the MND to act operate as a slave device in order to be programmed using the APG Modbus software NOTE the Sensor Address parameter see below is used to set the MND s own...

Страница 19: ...for the register to be displayed 3 holding resister 4 input register Sensor readings are stored in input registers while sensor parameter values are stored in holding registers REGTYP Register Type se...

Страница 20: ...s No select Yes to write the new register value and complete the procedure or No to cancel the write and return to the Communications menu Write function example changing the Empty Distance value regi...

Страница 21: ...cent Full feature select PCTFUL in the main menu Select the sensor number you want to display as a percentage of full and enter the value associated with 100 0 empty is assumed to be 0 Setting the val...

Страница 22: ...ved configuration back to the MND see page 25 Use the following steps to establish communications and program the MND via the APG Modbus software Step 1 Use the buttons on the MND to enter the Communi...

Страница 23: ...ssigned to the RS 485 to RS 232 converter being used Step 7 Select MND Step 6 Ensure Sensor matches the Sensor Address setting in the MND Step 8 Once all the changes have been made click Save Config t...

Страница 24: ...he MND Step 11 To change multiple parameters individually click on the values you wish to change enter the desired values then click the Send All button at the bottom of the window to write all the va...

Страница 25: ...eviously saved settings configuration to the MND click on File then se lect Load Mode Values Choose a file you wish to upload then click Open This will load the parameter values into the software Clic...

Страница 26: ...1 6 C Type Master Number of Sensors 6 Sensor Address 3 Register Number 303 Function 4 Register Type U32 unsigned 32 bit MND in Sniffer mode displaying readings from a single sensor address 3 C Type S...

Страница 27: ...Shift 0 Multiplier 1 000 Bar Graph 0 0 Bar Graph 100 10000 Over Load 99999 max display value Battery Gauge Enable No Battery Battery Full 13 5 V Battery Low 11 0 V Analog Low Reading 0 Analog High Re...

Страница 28: ...Output Input Voltage Requirements 9 Vdc min no load to 28 Vdc max Signal Variance 0 16 mA at set points Output Input 2 wire loop powered Resolution 14 bit Protection reversed polarity 0 3 VDC Output I...

Страница 29: ...407 U16 Empty Distance 0 to 10364 mm 40408 U16 Sensitivity 0 to 100 40409 U16 Pulses 0 to 20 40410 U16 Blanking 0 to 10364 mm 40411 U16 Gain Control 0 to 4 40412 U16 Averaging 0 to 100 40413 U16 Filte...

Страница 30: ...m 40407 U16 Empty Distance 0 to 10364 mm 40408 U16 Sensitivity 0 to 100 40409 U16 Pulses 0 to 20 40410 U16 Blanking 0 to 10364 mm 40411 reserved 40412 U16 Averaging 0 to 100 40413 U16 Filter Window 0...

Страница 31: ...AUTOMATION To order additional copies of this manual ask for APG document number 9003708 Rev A 6 15 P R O D U C T S GROUP INC Automation Products Group Inc www com information itm com 1 800 561 8187...