A54-3002-027
• Rev B
17
APCON, Inc.
Bypass Switch TAP/Aggregator User Manual
Chapter 2 Introduction
Alarms
The following summarizes additional discussion concerning alarms:
• If a pair of Network ports are set to Monitor (Normal) mode or the blade loses power, then
the paired ports are placed in alarm mode.
• If a pair of Network ports are set to Monitor (Normal) mode and the ports go into Bypass
mode (for a reason other than the being set manually to Bypass mode), then the paired
ports are placed in alarm mode.
• If a pair of Network ports are set to Monitor (Normal) mode, and power to the blade is
recycled, all Network paired ports are placed in Bypass mode (default). The paired ports
that were in Monitor (Normal) mode are switched to Bypass mode and placed in alarm
mode.
• If the paired Network ports that are in alarm mode are set to Monitor (Normal) mode and
heartbeats are sent and received properly, the alarms for those ports are cleared.