1. I

NTRODUCTION

Radio madule E-RM 30 scans the data from specially designed water meter, processes them, save to the
memory and transmits data via radio signal. Data sent by radio interface can be read without entering the flat
and even entering the building. E-RM 30 together with electronic heat cost allocators E-ITN 30 protect your
privacy and save your time due to remote data reading.

E-RM 30 rod antenna features a very good efficiency. Deu to this high-quality signla it is possible to read
data without entering the building eve in case of installation in the shaft of multiplestorey building. Data
reading can be made by billing company employee using mobile receiving unit. Data can be also read by
central reading system CRS 40 permanently installed in the building if required. If radio heat cost allocators
E-ITN 30 are also used, data are read simultaneously.

Every user can control current value on analogue dial of water meter. In contrast to the traditional water
meter,   radio   module   E-RM   30   distinguish   the   direction   of   water   flow   –   it   is   thus   possible   to   detect
manipulation with water meter (its turning). 

The radio module can be of course secured by conventional mechanical seal against its removal from water
meter.   The   radio   module   is   equipped   with   an   electronic   seal   that   allows   you   to   identify   unauthorized
manipulation and record the exact date. Furthemore, some modelas can detect attemps to manipulate the
water meter by the use of an externam magnetic field (e.g. the use of a strong magnet). Information about
such manipulation is transmitted in radio signal.  

Month consumptions for forward and back flow for past 12 months can be read from the radio module
memory via infra-red interface.

3 / 17

Illustration 1: Radio module E-RM 30 with water meter JS

radio module E-RM 30

water meter JS

antenna

IR diode for infra-red 

reading

preparation for 

mechanical seal

water meter dial

reading sensors

Содержание E-RM 30

Страница 1: ...RADIO MODULE FOR WATER METER E RM 30 Installation and service manual APATOR METRA s r o Havl kova 919 24 787 64 umperk tel 420 583 718 111 fax 420 583 718 150 e mail prodej metra su cz www http www m...

Страница 2: ...mode 9 5 3 2 Switch a radio module to the mode of automatic activation 9 5 3 3 Switch a radio module to the sleeping mode 10 5 4 Electronic seal reactivation 10 6 OTHER INFORMATIONS 10 6 1 Transportin...

Страница 3: ...are also used data are read simultaneously Every user can control current value on analogue dial of water meter In contrast to the traditional water meter radio module E RM 30 distinguish the directio...

Страница 4: ...dio module is equipped with electronic seals and also the option to use mechanical seals in order to safeguard the module from tampering If there is an unauthorised removal of the module from the mete...

Страница 5: ...of measured values including real time Function control automatic Dimensions 70 x 44 x 71 mm Power suply lithium battery 3 V Calculat battery lifetime e g chapter 2 1 Type list Material polycarbonate...

Страница 6: ...ion in past billing period back flow consumption in billing period before last standard flow consumption in billing period before last back flow date of electronic seal activation date of electronic s...

Страница 7: ...n consists only from putting module on water meter and installation of mechanical seal In mode of automatic activation module regulary tests disc presence If the presence is detected measuring of wate...

Страница 8: ...reading unit IRU 10 00 The IRU 10 00 displays information related to the last unit it has read It is therefore necessary to carry out a data reading from the radio module so that you can view the par...

Страница 9: ...l mode change is indicated by a single beep and the display showing o Pro 5 An unsuccessful mode change is indicated by four beeps and the display showing E Pro For more informations refer to the Inst...

Страница 10: ...adio module is now in working mode and has broken electronic seal 2 Cover optical sensors with black cover used during module trasportation 3 Switch a radio module to the sleeping mode with an infra r...

Страница 11: ...ntrary to installation and service manual or damaged during transport or storage by customer or reseller when mounted or dismantled to the customer device because of improper handling or installation...

Страница 12: ...E RM 30 Installation and service manual M2016 09f EN 12 17 Illustracion 3 Packing sheet...

Страница 13: ...et of water which pushes ifs blades along the vane perimeter and it is the only movable element submerged in water Rotor rotation is conveyed by a magnetic head clutch through the sealing plate Dry co...

Страница 14: ...ion notified person number flow direction as an arrow V or H marking for vertical or horizontal pipes or both jet flow value Q3 Q1 andr Q3 ratio marking of measurement unit in m3 on the counter dial v...

Страница 15: ...k between a valve and a strraight pipe section and before the water meter 5 For an installation of a water meter which does not cause strain in the body it is recommended to use compensative connector...

Страница 16: ...tion and the filter if it is used should be cleaned During flushing use a spigot to replace the water meter 2 Before installation check the operation of a water meter by starting a rotating motion of...

Страница 17: ...alternative connector JS 90 2 5 G1 8 3 WATER METER GSD8 RF Nominal flow Qn 1 5 m3 h Maximal flow Qmax 3 m3 h Max working pressure 16 bar Class of accuracy B horizontal installing A vertical installing...

Отзывы: