the water meter well and additionally the water meter and its equipment should be installed far
enough from the well bottom. 

2. In the  location of  installation, the  water meter connot be at risk of  being  hit  or  be subjected to

vibrations caused   by  other  devices  in   the  vicinity or  subjected   to   high  ambient   air  temperature,
contamination, flooding and corrosive action of the surroumdings.   Temperature in the installation
location should not be lower than 4 °C. The water meter should be protected from influence of such
hydraulic phenomena such as cavitation or hydrodynamic water hammering.

3. Before and after the water meter provide the valves in order to cut off the water supply if there is

need for deinstallation or repair. Use valves which can entirely reveal the cross – section of a water
pipe.

4. In case of expected water contamination during time of operation, install a filter or a setting tank

between a valve and a strraight pipe section and before the water meter.

5. For an installation of a water meter which does not cause strain in the body it is recommended to

use compensative connectors installed at the output.

6. The pipe in the installaton lacation should be shaped so that there is no possibillity for an air pocket

to be created in the water meter. Water meter has to be entirely filled with water, so the water pipe
after the water meter cannot decline. (Illustration 5: Water meter installation).

7. Water meter should mot be under risk of excessive strain caused by pipelines and equipment. If

necessary, install it on a pedestal or in a grip. What is more, the pipes connecting on the inlet and
outlet side should be adequately fastened, so that no part of the system is dislocated by the water
when the water meter is deinstalled or disconnected from one side.

8. During installing a meter in the water network, observe the correct water meter orientation according

to   the   design:   for   horizontal,   vertical   and   diagonal   operation.   (Ilustration   6:   Sample   permitted
installation positions)
.

15 / 17

Illustration 5: Water meter installation

water meter

Содержание E-RM 30

Страница 1: ...RADIO MODULE FOR WATER METER E RM 30 Installation and service manual APATOR METRA s r o Havl kova 919 24 787 64 umperk tel 420 583 718 111 fax 420 583 718 150 e mail prodej metra su cz www http www m...

Страница 2: ...mode 9 5 3 2 Switch a radio module to the mode of automatic activation 9 5 3 3 Switch a radio module to the sleeping mode 10 5 4 Electronic seal reactivation 10 6 OTHER INFORMATIONS 10 6 1 Transportin...

Страница 3: ...are also used data are read simultaneously Every user can control current value on analogue dial of water meter In contrast to the traditional water meter radio module E RM 30 distinguish the directio...

Страница 4: ...dio module is equipped with electronic seals and also the option to use mechanical seals in order to safeguard the module from tampering If there is an unauthorised removal of the module from the mete...

Страница 5: ...of measured values including real time Function control automatic Dimensions 70 x 44 x 71 mm Power suply lithium battery 3 V Calculat battery lifetime e g chapter 2 1 Type list Material polycarbonate...

Страница 6: ...ion in past billing period back flow consumption in billing period before last standard flow consumption in billing period before last back flow date of electronic seal activation date of electronic s...

Страница 7: ...n consists only from putting module on water meter and installation of mechanical seal In mode of automatic activation module regulary tests disc presence If the presence is detected measuring of wate...

Страница 8: ...reading unit IRU 10 00 The IRU 10 00 displays information related to the last unit it has read It is therefore necessary to carry out a data reading from the radio module so that you can view the par...

Страница 9: ...l mode change is indicated by a single beep and the display showing o Pro 5 An unsuccessful mode change is indicated by four beeps and the display showing E Pro For more informations refer to the Inst...

Страница 10: ...adio module is now in working mode and has broken electronic seal 2 Cover optical sensors with black cover used during module trasportation 3 Switch a radio module to the sleeping mode with an infra r...

Страница 11: ...ntrary to installation and service manual or damaged during transport or storage by customer or reseller when mounted or dismantled to the customer device because of improper handling or installation...

Страница 12: ...E RM 30 Installation and service manual M2016 09f EN 12 17 Illustracion 3 Packing sheet...

Страница 13: ...et of water which pushes ifs blades along the vane perimeter and it is the only movable element submerged in water Rotor rotation is conveyed by a magnetic head clutch through the sealing plate Dry co...

Страница 14: ...ion notified person number flow direction as an arrow V or H marking for vertical or horizontal pipes or both jet flow value Q3 Q1 andr Q3 ratio marking of measurement unit in m3 on the counter dial v...

Страница 15: ...k between a valve and a strraight pipe section and before the water meter 5 For an installation of a water meter which does not cause strain in the body it is recommended to use compensative connector...

Страница 16: ...tion and the filter if it is used should be cleaned During flushing use a spigot to replace the water meter 2 Before installation check the operation of a water meter by starting a rotating motion of...

Страница 17: ...alternative connector JS 90 2 5 G1 8 3 WATER METER GSD8 RF Nominal flow Qn 1 5 m3 h Maximal flow Qmax 3 m3 h Max working pressure 16 bar Class of accuracy B horizontal installing A vertical installing...

Отзывы: