E-RM 30

 Installation and service manual

 M2016/09f[EN] 

5. W

ORK

 

WITH

 

A

 

RADIO

 

MODULE

5.1. I

NSTALLATION

 E-RM 30 

TO

 

THE

 

WATER

 

METER

1. Check   the   condition   of   the   intended   water   meatier   and   its   housing.   If   there   is   any   damage   or

contamination, clean or replace the meter.

2. Remove the cardboard plugs which are used to protect the E-RM 30 radio module's sensors during

transport. Retain the plugs for covering the sensors during any modes changes (5.3  Change of
operation mode)
.

3. Attach   the   radio   module   to   the   water   meter   using   the   snap-on   lock   and   then   seal   it.   It   is

recommended that plastic or adhesive paper seals are used.

4. Activate the radio module depending on the required operating mode.

5.2. R

EADING

 

DATA

DEFINING

 

PARAMETERS

 

AND

 

OPERATING

 

MODES

Given that the radio module RM E-30 is not equipped with a display, it is possible to obtain basic information
about the active mode, the start date of the billing period, and electronic seals using infrared reading unit
IRU 10.00.

The IRU 10.00 displays information related to the last unit it has read. It is therefore necessary to carry out a
data reading from the radio module so that you can view the parameters and operating mode. During the
reading it is necessary to put on the viewing screen so as to avoid interference from ambient light sources.
The front of the meter reading head should be in contact with the plastic cover of the infrared reading diodes
inside the unit (e.g. Illustration 2: Data reading from E-RM 30 with IRU 10.00).

For more information about reading data, display parameters and operating mode, refer to the Installation
and service manual for the IRU 10.00.

5.3. C

HANGE

 

OF

 

OPERATION

 

MODE

Using the infrared reading unit, the IRU 10.00, it is possible to change the operating modes of the E-RM30.
In individual operating modes it is only possible to make certain changes (see table below). It is therefore
advisable to first check the current operating mode of the radio module (e.g. chapter  5.2.  Reading data,
defining parameters and operating modes)
 and then change the mode.

8 / 17

Illustration 2: Data reading from E-RM 30 with IRU 10.00

Содержание E-RM 30

Страница 1: ...RADIO MODULE FOR WATER METER E RM 30 Installation and service manual APATOR METRA s r o Havl kova 919 24 787 64 umperk tel 420 583 718 111 fax 420 583 718 150 e mail prodej metra su cz www http www m...

Страница 2: ...mode 9 5 3 2 Switch a radio module to the mode of automatic activation 9 5 3 3 Switch a radio module to the sleeping mode 10 5 4 Electronic seal reactivation 10 6 OTHER INFORMATIONS 10 6 1 Transportin...

Страница 3: ...are also used data are read simultaneously Every user can control current value on analogue dial of water meter In contrast to the traditional water meter radio module E RM 30 distinguish the directio...

Страница 4: ...dio module is equipped with electronic seals and also the option to use mechanical seals in order to safeguard the module from tampering If there is an unauthorised removal of the module from the mete...

Страница 5: ...of measured values including real time Function control automatic Dimensions 70 x 44 x 71 mm Power suply lithium battery 3 V Calculat battery lifetime e g chapter 2 1 Type list Material polycarbonate...

Страница 6: ...ion in past billing period back flow consumption in billing period before last standard flow consumption in billing period before last back flow date of electronic seal activation date of electronic s...

Страница 7: ...n consists only from putting module on water meter and installation of mechanical seal In mode of automatic activation module regulary tests disc presence If the presence is detected measuring of wate...

Страница 8: ...reading unit IRU 10 00 The IRU 10 00 displays information related to the last unit it has read It is therefore necessary to carry out a data reading from the radio module so that you can view the par...

Страница 9: ...l mode change is indicated by a single beep and the display showing o Pro 5 An unsuccessful mode change is indicated by four beeps and the display showing E Pro For more informations refer to the Inst...

Страница 10: ...adio module is now in working mode and has broken electronic seal 2 Cover optical sensors with black cover used during module trasportation 3 Switch a radio module to the sleeping mode with an infra r...

Страница 11: ...ntrary to installation and service manual or damaged during transport or storage by customer or reseller when mounted or dismantled to the customer device because of improper handling or installation...

Страница 12: ...E RM 30 Installation and service manual M2016 09f EN 12 17 Illustracion 3 Packing sheet...

Страница 13: ...et of water which pushes ifs blades along the vane perimeter and it is the only movable element submerged in water Rotor rotation is conveyed by a magnetic head clutch through the sealing plate Dry co...

Страница 14: ...ion notified person number flow direction as an arrow V or H marking for vertical or horizontal pipes or both jet flow value Q3 Q1 andr Q3 ratio marking of measurement unit in m3 on the counter dial v...

Страница 15: ...k between a valve and a strraight pipe section and before the water meter 5 For an installation of a water meter which does not cause strain in the body it is recommended to use compensative connector...

Страница 16: ...tion and the filter if it is used should be cleaned During flushing use a spigot to replace the water meter 2 Before installation check the operation of a water meter by starting a rotating motion of...

Страница 17: ...alternative connector JS 90 2 5 G1 8 3 WATER METER GSD8 RF Nominal flow Qn 1 5 m3 h Maximal flow Qmax 3 m3 h Max working pressure 16 bar Class of accuracy B horizontal installing A vertical installing...

Отзывы: