background image

E-RM 30

 Installation and service manual

 M2016/09f[EN] 

2. D

ESCRIPTION

Radio module E-RM 30 is intended for record of data about consumed water – measured by mechanical
water meter –  and for  remote  reading of  these  data.  Mechanical  water meter is equipped with  rotating
circular disc with reflecting sector. Radio module permanently scan the surface of the disc – its speed and
rirection   of  rotation.  Amount   of   consumed   water  is  recorded   and  also  direction   of   flow  )forward   flow  or
backflow).

Radio   module   E-RM   does   not   dispose   of   display   –   is   equipped   with   IR   interface   with   bi-birectional
communication. Via this interface it is possible to set module parameters, switch between operational modes,
get informations about set parameters, module functions and measured values (e.g. chapter  5.2.  Reading
data, defining parameters and operating modes 
a 5.3. Change of operation mode).

Some models of the E-RM 30 (e.g. chapter 2.1. Type list) are able to detect attempts to manipulate the water
meter by using an external magnetic field (for example by using a magnet). The actual transfer of data
between the water meter and the radio module is based on an optical principle (just like the radio module
itself) and is therefore not affected by a magnetic field.  

The radio module is equipped with electronic seals (and also the option to use mechanical seals) in order to
safeguard the module from tampering. If there is an unauthorised removal of the module from the meter, the
device records and stores the date of the offence and   transmits this information by radio signal. The unit
remains in operating mode and after re-activation and re-setting it continues to measure the flow in the water
meter.

2.1. T

YPE

 

LIST

Radio   modules  E-RM  30  are   produced   in   several  types,   which   are   divergent   in   water  meter  made   for,
antenna size and skill of magnetic field detection. 

The type with short antenna (about 15mm) is determined to places where is not possible to use a standard
one. Due to the low signal is recommended - if it is possible – to use a module with standard antenna.

Type

Water meter

Antenna

Biling period

Calculat. battery

lifetime (year)

Magnetic field

detection

E-RM 30.101

GSD8-RF

standard

year

6+1 (reserve)

-

E-RM 30.102

month

E-RM 30.111

short

year

E-RM 30.112

month

E-RM 30.201

JS

standard

year

6+1 (reserve)

-

E-RM 30.202

month

E-RM 30.211

short

year

E-RM 30.212

month

E-RM 30.301

JS

standard

year

10+1 (reserve)

E-RM 30.302

month

Warning!

Radio modules are determined just for one water meter type. You CAN´T use it for another type. For
example   radio   module   E-RM   30.101   must   not   be   used   for   water   meter   JS.   The   manufacturer
assumes no liability for measurement mistakes caused by water meter substitation.

4 / 17

Содержание E-RM 30

Страница 1: ...RADIO MODULE FOR WATER METER E RM 30 Installation and service manual APATOR METRA s r o Havl kova 919 24 787 64 umperk tel 420 583 718 111 fax 420 583 718 150 e mail prodej metra su cz www http www m...

Страница 2: ...mode 9 5 3 2 Switch a radio module to the mode of automatic activation 9 5 3 3 Switch a radio module to the sleeping mode 10 5 4 Electronic seal reactivation 10 6 OTHER INFORMATIONS 10 6 1 Transportin...

Страница 3: ...are also used data are read simultaneously Every user can control current value on analogue dial of water meter In contrast to the traditional water meter radio module E RM 30 distinguish the directio...

Страница 4: ...dio module is equipped with electronic seals and also the option to use mechanical seals in order to safeguard the module from tampering If there is an unauthorised removal of the module from the mete...

Страница 5: ...of measured values including real time Function control automatic Dimensions 70 x 44 x 71 mm Power suply lithium battery 3 V Calculat battery lifetime e g chapter 2 1 Type list Material polycarbonate...

Страница 6: ...ion in past billing period back flow consumption in billing period before last standard flow consumption in billing period before last back flow date of electronic seal activation date of electronic s...

Страница 7: ...n consists only from putting module on water meter and installation of mechanical seal In mode of automatic activation module regulary tests disc presence If the presence is detected measuring of wate...

Страница 8: ...reading unit IRU 10 00 The IRU 10 00 displays information related to the last unit it has read It is therefore necessary to carry out a data reading from the radio module so that you can view the par...

Страница 9: ...l mode change is indicated by a single beep and the display showing o Pro 5 An unsuccessful mode change is indicated by four beeps and the display showing E Pro For more informations refer to the Inst...

Страница 10: ...adio module is now in working mode and has broken electronic seal 2 Cover optical sensors with black cover used during module trasportation 3 Switch a radio module to the sleeping mode with an infra r...

Страница 11: ...ntrary to installation and service manual or damaged during transport or storage by customer or reseller when mounted or dismantled to the customer device because of improper handling or installation...

Страница 12: ...E RM 30 Installation and service manual M2016 09f EN 12 17 Illustracion 3 Packing sheet...

Страница 13: ...et of water which pushes ifs blades along the vane perimeter and it is the only movable element submerged in water Rotor rotation is conveyed by a magnetic head clutch through the sealing plate Dry co...

Страница 14: ...ion notified person number flow direction as an arrow V or H marking for vertical or horizontal pipes or both jet flow value Q3 Q1 andr Q3 ratio marking of measurement unit in m3 on the counter dial v...

Страница 15: ...k between a valve and a strraight pipe section and before the water meter 5 For an installation of a water meter which does not cause strain in the body it is recommended to use compensative connector...

Страница 16: ...tion and the filter if it is used should be cleaned During flushing use a spigot to replace the water meter 2 Before installation check the operation of a water meter by starting a rotating motion of...

Страница 17: ...alternative connector JS 90 2 5 G1 8 3 WATER METER GSD8 RF Nominal flow Qn 1 5 m3 h Maximal flow Qmax 3 m3 h Max working pressure 16 bar Class of accuracy B horizontal installing A vertical installing...