1. 

PRINCIPLES OF SAFE USE

 

 

before you start to use the device, become familiar with the present instructions; 

 

make sure that all wires are connected properly to the tested item; 

 

wire connections must be modified only with voltage switched off; ensure proper operating conditions compliant 

with the technical specification of the device (signal level, humidity, temperature, etc.; see chapter 4); 

The device is designed so as to ensure an appropriate level of immunity to most interferences that may occur in 
industrial environments. In environments of unknown level of interferences, it is recommended to implement the 
following measures so as to prevent potential interference with the operation of the device: 

 

avoid running signal cables in the direct vicinity of and parallel to power and supply cables; 

 

it is recommended to use twisted pair signal cables; 

 

avoid proximity of remotely controlled devices, electromagnetic meters, high power loads, loads with phase or 

group power control, and other devices that cause high impulse disturbances; 

 

use shielded signal cables, whereby the earthing of the shield should be single-point and located as close to 

the device as possible; 

 

ground or zero metal rails on which rail-mounted devices are installed.

 

 

Make sure to remove the protective film from the LCD display before the first use of the device.

 

 

2. GENERAL CHARACTERISTICS OF THE SETTER

 

 

the device is intended for setting or measuring standard current and voltage signals; 

 

analog output/input (setter or measuring device): 

 

current 0/4÷20 mA (active output, may not be supplied in a two-wire current loop) 

 

voltage 0/2÷10 V 

 

the output enables controlling or testing of equipment with current or voltage inputs (proportional valves, 

actuators, inverters, motors, etc.) 

 

soft start/stop (ramping) or triangular wave generator released and stopped manually 

 

programmable configuration parameters (range of indication, range and increment of output signal changes, 

soft start/stop options, time of automatic activation of the instrument, zero calibration, and amplification of 
the measured or set signal, etc.) 

 

quick and simple readout of: 

 

the real value of the output or measured signal (mA, V, or calculated as programmable indication range); 

 

type of set signal; 

 

operating direction; 

 

diagnostic messages presented on the display that facilitate detection of defects in the tested system, e.g. 

short circuits in the voltage signal circuit, breaks in the current loop circuit  

 

possible password protection of access to configuration parameters 

 

ergonomic manual enclosure with rubberized side grips 

 

simple and reliable laboratory banana connectors 

 

a clearly visible LCD display (without background illumination) and a functional keyboard 

 

power supply from two AA (R6) (rechargeable) batteries 

 

automatic shutdown after a preset idle time 

 

integrated battery charging system (power supply provided) 

 

automatic power supply cutoff at low battery charging level 

 

high resistance to interferences present in industrial environments 

 

available accessories: 

 

power supply for battery charging 

 

Содержание AR911

Страница 1: ...ruction AR911 Setter analog signal measuring device Version 1 0 2 2013 03 20 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Tel 48 22 101 27 31 48 22 853 49 30 E mail automatyka apar pl Website ww...

Страница 2: ...ER 3 3 CONTENTS OF THE SET 4 4 TECHNICAL DATA 4 5 DIMENSIONS OF THE ENCLOSUREAND DESCRIPTION OF CONNECTIONSAND ELEMENTS 5 6 BUTTON FUNCTIONS 6 7 RANGE OF INDICATIONS CHANGE OFAVALUE SET FOR AN OUTPUT...

Страница 3: ...measuring standard current and voltage signals analog output input setter or measuring device current 0 4 20 mA active output may not be supplied in a two wire current loop voltage 0 2 10 V the outpu...

Страница 4: ...mperature changes 0 005 of the input range C Output input response time 10 90 0 36 s output 0 32 1 3 s input programmable with parameter 6 FiLt A 7 segment LCD display without background illumination...

Страница 5: ...TION OF CONNECTIONS AND EXTERNAL ELEMENTS 1 Enclosure Enclosure type manual portable MBMO series Material ABS Enclosure dimensions 162 x 89 x 25 mm Protection rating IP43 IP20 on the connection side 2...

Страница 6: ...chapter 8 SET UP a stepwise limit change of the set value of the output signal upper value of the indication range 20 mA 10 V parameter 4 rtoP or setting range reduction 8 LiLo SET DOWN a stepwise li...

Страница 7: ...THE CONFIGURATION PARAMETERS All the configuration parameters of the device are stored in the non volatile EEPROM internal memory The parameters are set from the film keypad located on the front panel...

Страница 8: ...tput setting mode also set using the OUT button 8 LiLo lower setting limit 999 9999 units lower limit of the set value parameter 11 SEt when setting using the setter buttons 9 99 9 LiHi upper setting...

Страница 9: ...es are different than zero 12 riSE and 13 FALL a periodic triangular signal is generated on the outputs The limit values amplitudes of the output signal are equal to the limit values of the signal use...

Страница 10: ...errors one time and recurring Code Description of message the operating mode was initiated input output PoFF the calibrator was switched off manually or automatically due to low battery voltage CodE...

Страница 11: ...11 11 USER S NOTES...

Страница 12: ...12...

Отзывы: