APAR AR911 Скачать руководство пользователя страница 2

2

 

Thank you for choosing our product. 

This instruction is intended to facilitate correct operation, safe use, and taking full 

advantage of the setter’s functionalities. 

Before you start the device, please read and understand this instruction. 

In the event of any additional questions, please contact our technical adviser.

 

 

CONTENTS 

 

1. PRINCIPLES OF SAFE USE 

2. GENERAL CHARACTERISTICS OF THE SETTER 

3. CONTENTS OF THE SET 

4. TECHNICAL DATA 

5. DIMENSIONS OF THE ENCLOSURE AND DESCRIPTION OF  
     CONNECTIONS AND ELEMENTS 

6. BUTTON FUNCTIONS 

7. RANGE OF INDICATIONS. CHANGE OF A VALUE SET FOR AN OUTPUT 

8. SETTING OF THE CONFIGURATION PARAMETERS 

9. SOFT START/STOP AND TRIANGULAR WAVE GENERATOR 

10. MESSAGE AND ERROR SIGNALING. DIAGNOSTIC FUNCTIONS 

10 

11. USER'S NOTES 

11

 

 

Please pay particular attention to the text marked with this sign.

 

The manufacturer reserves the right to make changes to the design and the programming of the device without any deterioration of the technical 

parameters. 

 

 

 

 

 

 

 

 

 

!

Содержание AR911

Страница 1: ...ruction AR911 Setter analog signal measuring device Version 1 0 2 2013 03 20 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Tel 48 22 101 27 31 48 22 853 49 30 E mail automatyka apar pl Website ww...

Страница 2: ...ER 3 3 CONTENTS OF THE SET 4 4 TECHNICAL DATA 4 5 DIMENSIONS OF THE ENCLOSUREAND DESCRIPTION OF CONNECTIONSAND ELEMENTS 5 6 BUTTON FUNCTIONS 6 7 RANGE OF INDICATIONS CHANGE OFAVALUE SET FOR AN OUTPUT...

Страница 3: ...measuring standard current and voltage signals analog output input setter or measuring device current 0 4 20 mA active output may not be supplied in a two wire current loop voltage 0 2 10 V the outpu...

Страница 4: ...mperature changes 0 005 of the input range C Output input response time 10 90 0 36 s output 0 32 1 3 s input programmable with parameter 6 FiLt A 7 segment LCD display without background illumination...

Страница 5: ...TION OF CONNECTIONS AND EXTERNAL ELEMENTS 1 Enclosure Enclosure type manual portable MBMO series Material ABS Enclosure dimensions 162 x 89 x 25 mm Protection rating IP43 IP20 on the connection side 2...

Страница 6: ...chapter 8 SET UP a stepwise limit change of the set value of the output signal upper value of the indication range 20 mA 10 V parameter 4 rtoP or setting range reduction 8 LiLo SET DOWN a stepwise li...

Страница 7: ...THE CONFIGURATION PARAMETERS All the configuration parameters of the device are stored in the non volatile EEPROM internal memory The parameters are set from the film keypad located on the front panel...

Страница 8: ...tput setting mode also set using the OUT button 8 LiLo lower setting limit 999 9999 units lower limit of the set value parameter 11 SEt when setting using the setter buttons 9 99 9 LiHi upper setting...

Страница 9: ...es are different than zero 12 riSE and 13 FALL a periodic triangular signal is generated on the outputs The limit values amplitudes of the output signal are equal to the limit values of the signal use...

Страница 10: ...errors one time and recurring Code Description of message the operating mode was initiated input output PoFF the calibrator was switched off manually or automatically due to low battery voltage CodE...

Страница 11: ...11 11 USER S NOTES...

Страница 12: ...12...