NOTE:
Each fan stage is independent. Items turned on in previous stages are not automatically
turned on and need to be selected again for each fan in each desired stage.
3. Choose the mode of the Variable output status:
Option
Description
Variable (Var)
The variable fan output is assigned to the fan stage and operates in variable
mode: when the stage starts, the variable fan starts running at its minimum inten-
sity. The fan intensity gradually increases as the room temperature increases.
On
The variable fan output is assigned to the fan stage and operates in on/off mode:
the fan runs at 100% when the fan stage is on and stops when the stage is off.
Off
The variable output is not assigned.
NOTE:
If the last fan stage uses a variable output, the output must use the on/off operating mode.
Do not set the operating mode of the last fan stage to the variable mode.
4. Either put a checkmark to assign a relay to an output or select
Timer
if the load connected to the
relay must run in timer mode.
NOTE:
If timer-based relays are assigned to fan stages, set the
On Time
and the
Off Time
of the
timer.
Assigning Tunnel Curtain Relays
Relays 7-8 and relays 13-14 are designed to connect actuators. When actuators are connected to these
relays, their open and close relays can never be activated at the same time.
1. Using the menu select arrow keys, navigate to
Relay Settings→Tunnel→Tunnel Open or Tunnel
Close
.
NOTE:
This menu is only accessible if the tunnel curtain is enabled.
2. Put a checkmark beneath the relay used to open or close the tunnel curtain.
Assigning Inlet Relays
Relays 7-8 and relays 13-14 are designed to connect actuators. When actuators are connected to these
relays, their open and close relays can never be activated at the same time.
1. Using the menu select arrow keys, navigate to
Relay settings→Inlets→Inlet Open or Inlet Close
.
NOTE:
This menu is accessible if the inlet is enabled.
2. Put a checkmark beneath the relay used to open or close the air inlet.
Assigning Stir Fan Relays
1. Using the menu select arrow keys, navigate to
Relay Settings→Stir Fan
.
NOTE:
This menu is accessible if the stir fan output is enabled.
2. Put a checkmark beneath the relay used by the stir fan.
Assigning Cooling Output Relays
What You Should Know
24
890-00081
Expert VT-110
Содержание Expert VT-110
Страница 1: ...Expert VT 110 User Manual 890 00081 Version 24 REV 19...
Страница 6: ...NOTES 6 890 00081 Expert VT 110...
Страница 10: ...NOTES 10 890 00081 Expert VT 110...
Страница 12: ...NOTES 12 890 00081 Expert VT 110...
Страница 22: ...NOTES 22 890 00081 Expert VT 110...
Страница 26: ...NOTES 26 890 00081 Expert VT 110...
Страница 32: ...NOTES 32 890 00081 Expert VT 110...
Страница 46: ...NOTES 46 890 00081 Expert VT 110...
Страница 50: ...Chapter 13 Stir Fan 50 890 00081 Expert VT 110...
Страница 52: ...NOTES 52 890 00081 Expert VT 110...
Страница 64: ...NOTES 64 890 00081 Expert VT 110...
Страница 76: ...NOTES 76 890 00081 Expert VT 110...
Страница 78: ...NOTES 78 890 00081 Expert VT 110...
Страница 79: ...A Worksheets 890 00081 Expert VT 110 79...
Страница 80: ...Appendix A Worksheets 80 890 00081 Expert VT 110...
Страница 81: ...Appendix A Worksheets 890 00081 Expert VT 110 81...
Страница 82: ...NOTES 82 890 00081 Expert VT 110...