![Anyload 805BS Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/anyload/805bs-series/805bs-series_manual_2948859009.webp)
- 7 -
count items.
1.5.3.3 Zero Scale
When in Gross mode (The “Gross” symbol is displayed), remove the load from scale. When
the “Stable” symbol is displayed, press
【
ZERO
】
and “Zero” symbol is displayed. Zero Scale
setting is complete.
1.5.3.4 Acquire Tare
When no Tare is stored (No “Tare” symbol is displayed), place the container onto the scale
and wait until the “Stable” symbol is displayed. Press
【
TARE
】
and Tare value (weight of
container) is stored. Display shows Net weight and the “Net” symbol is displayed (refer to
F6.1 Menu).
1.5.3.5 Remove Stored Tare Value
When a tare value is stored (The “Tare” symbol is displayed), press
【
TARE
】
and the stored
tare value is removed. Display shows Gross weight and the “Gross” symbol is displayed
(refer F6.1 Menu).
1.5.3.6 Input Item Code
When in Count mode, press
【
】
to go to Input Item Code status. Display shows “P=
xx”, where xx is the code number of the current count item and x flashes.
Now the functions of the keypad become
,
,
,
,
.
,
are for moving
forward and backward while
,
are for increasing and decreasing the digits.
After finish with Input Item Code, press
key if the stored Item Code is not 0. Item Code
of the current count items is stored and the keypad returns to normal operating functions as
shown in Fig. 1-1.
If the stored Item Code = 0, display goes to the Fast Setup of the Averaging Weight of the
Count Item (refer to Section 1.5.3.7).
1.5.3.7 Fast Setup of Count Items Average Weight
To obtain the average weight of a count item without going into the Configuration mode,
follow the procedure below,
(1)
Enter the Input Item Code according to Section 1.5.3.6. Set the Item Code = 0.
Display shows “P = 00”.
(2)
Remove all weights from the scale. Press
to zero the scale. Display shows
“CAL” while calibration is in progress.
(3)
After zeroing the scale, display proceeds to Count Items Average Weight Setup.
Use
,
to select the suitable sample quantity. Normally select larger quantity
for lighter count items.
(4)
After selecting a suitable quantity and placing the respective quantity of count items
to the scale, press
. Display shows “CAL” while calibration is in progress. When
Содержание 805BS Series
Страница 1: ...805BS INDICATOR MANUAL www anyload com ...
Страница 16: ... 14 3 2 1 F1 Configuration Menu Fig 3 4 F1 Configuration Menu Structure ...
Страница 50: ... 48 9 4 ASCII Codes Table ...
Страница 51: ... 49 9 5 805BS Display Characters ...