![Anyload 805BS-B-17 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/anyload/805bs-b-17/805bs-b-17_operation-manual_2948860050.webp)
14.2.1 Data Transmission Sequence
Transmission Format from PC:
Fig. 14.2.1 Transmission Format from PC
Example: Set BLACK to “G” (which is 47H) in ASCII code. Inspection
and BCC calculation are as follow:
ASCII
HEX
BCC
G
47H
47H
ETX
03H
44H
30H
74H
“OR” with 30H
49
|