![Anyload 805BS-B-17 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/anyload/805bs-b-17/805bs-b-17_operation-manual_2948860015.webp)
Note: In this procedure, the settings for count items average weight will be
erased once the indicator is switched to other mode or the indicator is
restarted. If you want to save a count items average weight settings
refer to section Section 11
.
8.
Wire Installation
.
Fig. 8.1 Sockets on Circuit Board for 805TS & 805BS series
Note: When connect to 4-wire load cell, please turn SW1 ON.
When connect to 6-wire load cell, please turn SW1 OFF.
SW3 SW4
14
|
ANYLOAD 805TS & 805BS Series Weighing Indicator Operations Manual (v1703)
sample quantity set in (3) above. Press to calculate the
average weight.
-
Press
to cancel Count Items Average Weight Setup and
return to the Weighing mode.
Display shows the count items average weight and returns to the
Weighing mode.
(5)
On
the Weighing mode, keypad functions
are according in Fig.4.1
(805TS and Fig.4.2 (805BS series).