7.3.2 Units
Pressing the
【
UNITS
】
button will switch between the weight of load and the
quantity of count items. When showing the weight of load, follow F2.3 Menu to
choose the unit (refer to F2.3 Menu). When showing the quantity of count
items, the display shows “nxxxxx”. xxxxx is the quantity of c
ount items.
7.3.3 Zero Scale
When in Gross mode (for 805TS series, the “Gross” light is on; for 805B
S series
the “Gross” symbol is displayed),
remove the load from scale. After the “Stable”
light is on (805TS series), or the “Stable” sym
bol is displayed
(805BS series),
pressing the
【
ZERO
】
button the “Zero” light or symbol will be on. The Zero
Scale setting is now complete.
7.3.4 Acquire Tare
When no Tare is stored (“Tare” light or symbol is off), place the container onto
the scale and wait until the “Stable” light is on (805TS series), or “Stable”
symbol is displayed (805BS series). Press
【
TARE
】
and Tare value (weight of
container) is stored. The display will show the Net weight and the “Net” light
(805TS series) will be on, or the “Net” symbol will be displayed (805BS series)
(refer to F6.1 Menu).
Note: Only when the tare value displayed is less than 6 digits the tare value
can be successfully stored, otherwise, the tare option will not activate.
7.3.5 Remove Stored Tare Value
When a tare value is stored (for the 805TS series, the “Tare” light is on; for the
805BS series, the “Tare” symbol is displayed), press
【
TARE
】
to remove the
stored value. The display will show the Gross weight and the “Gross” light
(805TS series) will be on, or the “Gross” symbol (805BS series) will be displayed
(refer F6.1 Menu).
7.3.6 Input Item Code
When in Count Mode,
press
【
】
to go to Input Item Code status. Display
shows “P= xx”, where xx is the code number of the current count item and x
flashes. Now the functions of the keypad become
,
,
,
,
.
12
|
ANYLOAD 805TS & 805BS Series Weighing Indicator Operations Manual (v1703)