![Anyload 805BS-B-17 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/anyload/805bs-b-17/805bs-b-17_operation-manual_2948860039.webp)
Fig. 11.1 Count Items Average Weight Setup Menu
Setup procedures are as follows:
(
1
)
Turn on the SW2 switch to set indicator to the Configuration mode
(display shows “F1”).
(
2
)
Press until display shows “F5” (see Fig 11.1). Press
and the
display will show “F5.1”. Press
then press until F5.1 = 2. Next
press
to save the value. Once the value is saved, “F5.2” is
displayed.
(
3
)
Press
when display shows “F5.2”. Display shows and asks a code
number for your count items average weight settings. The code
number will be saved in the memory and represents the code for
your count items average weight settings. The code numbers are
from 01 to 99. The code “00” is reserved for Fast Setup of Count
Items Average Weight ( refer to Section 7.3.8 ). Follow the procedure
in Fig. 10.2 to input and edit the code number. Press
to save the
code number and proceed to the next menu. The display shows
“F5.3”.
(
4
)
Remove all the weight from the scale platform when display shows
“F5.3”. Press to zero the scale. Display shows “CAL” while
processing the zeroing operation. When completed
, display shows
“F5.4”
(
5
)
Press
when display shows “F5.4”. Display shows the sampling
quantity of the count items. Use
,
keys to specify the sampling
quantity. Place the samples in the platform of the scale. The quantity
of the samples must be the same with what you specified in the
sampling quantity. Press
to proceed to the next menu. Display
shows “F5.5”.
(
6
)
Press
when display shows “F5.5”. Display shows “CAL” while
processing the average weight setting. When completed
, there are
two (2) possible outcomes :
The average weight is too small and display shows “—E5—“.
Press
to return to F5.5 Menu and display shows “F5.5”. There
38
|
ANYLOAD 805TS & 805BS Series Weighing Indicator Operations Manual (v1703)