46 (70)
#
Name
Ac-
cess
Data Type
Default
Value
Comment
17
IP address byte
0–2
Get
Array of
UINT8[3]
[0] = 192
[1] = 168
[2] = 0
First three bytes in IP address. Used in standalone shift
register mode if the configuration switch value is set to 1-
245. In that case the IP address will be set to:
Y[0].Y[1].Y[2].X
Where Y0-2 is configured by this attribute and the last
byte X by the configuration switch.
18
Ethernet PHY
Configuration
Get
Array of
BITS16
0x0000 for
each port
Ethernet PHY configuration bit field. The length of the ar-
ray shall equal the number of Ethernet ports of the prod-
uct. Each element represents the configuration of one
Ethernet port (element #0 maps to Ethernet port #1, ele-
ment #1 maps to Ethernet port #2 and so on).
Note
: Only valid for EtherNet/IP and Modbus-TCP
devices.
Bit 0:
Auto negotiation fallback duplex
0 = Half duplex
1 = Full duplex
Bit 1–15:
Reserved
20
SNMP read-only
community string
Get
Array of
CHAR
“public”
Note
: This attribute is only valid for PROFINET devices.
Sets the SNMP read-only community string. Max length is
32.
21
SNMP read-write
community string
Get
Array of
CHAR
“private”
Note
: This attribute is only valid for PROFINET devices.
Sets the SNMP read-write community string. Max length
is 32.
22
DHCP Option 61
source
Get
ENUM
0 (Disabled)
Note
: This attribute is currently only valid for Ethernet/IP
devices.
See below (DHCP Option 61, Client Identifier)
23
DHCP Option 61
generic string
Get
Array of
UINT8
N/A
Note
: This attribute is currently only valid for Ethernet/IP
devices.
See below (DHCP Option 61, Client Identifier)
24
Enable DHCP
Client
Get
BOOL
1 = True
Note
: This attribute is currently only valid for Ethernet/IP
devices.
Enable/disable DHCP Client functionality
0:
DHCP Client functionality is disabled
1:
DHCP Client functionality is enabled
Network Status
This attribute holds a bit field which indicates the overall network status as follows:
Bit
Contents
Description
Comment
0
Link
Current global link status
1= Link sensed
0= No link
1
IP established
1 = IP address established
0 = IP address not established
2
(reserved)
(mask off and ignore)
3
Link port 1
Current link status for port 1
1 = Link sensed
0 = No link
EtherCAT only: This link status indicates whether
the Anybus CompactCom is able to communicat
using Ethernet over EtherCAT (EoE) or not. That
is, it indicates the status of the logical EoE port
link and is not related to the link status on the
physical EtherCAT ports.
4
Link port 2
Current link status for port 2
1 = Link sensed
0 = No link
Not used for EtherCAT
5... 15
(reserved)
(mask off and ignore)
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1