35 (70)
Instance Attributes (Instance #17, MDI 2 Settings )
This instance holds the settings for MDI/MDIX 2. Changes have immediate effect.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“MDI 2”
2
Data type
Get
UINT8
08h (= ENUM)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
ENUM
Value (ENUM):
00h
01h
02h
String: Meaning:
“Auto” (default)
“MDI”
“MDIX”
6
Configured Value
Get
ENUM
Holds the configured value, which will be written to attribute #5
after the module has been reset.
Value (ENUM):
00h
01h
02h
String: Meaning:
“Auto” (default)
“MDI”
“MDIX”
Instance Attributes (Instances #18 and #19)
These instances are reserved for future attributes.
Instance Attributes (Instance #20, Modbus connection timeout)
This instance holds the settings for the Modbus connection timeout. Changes will be applied to new connec-
tions. Existing connections will use the previous timeout value.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Conn tmo”
(Multilingual, see page
)
2
Data type
Get
UINT8
05h (= UINT16)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
UINT16
Value:
0
60
Meaning (seconds):
Timeout disabled
Default
6
Configured Value
Get
UINT16
Holds the configured value, which will be written to attribute #5.
Value:
0
60
Meaning (seconds):
Timeout disabled
Default
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1