25 (70)
8.2
Anybus Object (01h)
Category
Basic, extended
Object Description
This object assembles all common Anybus data, and is described thoroughly in the general
Anybus
CompactCom 40 Software Design Guide
.
Instance attribute #16 has to be set to 0002h during SETUP state to enable Transparent
Ethernet functionality.
Supported Commands
Object:
Get_Attribute
Instance:
Get_Attribute
Set_Attribute
Get_Enum_String
Object Attributes (Instance #0)
(Consult the general
Anybus CompactCom 40 Software Design Guide
for further information.)
Instance Attributes (Instance #1)
Basic
#
Name
Access
Type
Value
1
Module type
Get
UINT16
0403h (Standard Anybus CompactCom 40)
2... 11
-
-
-
Consult the general Anybus CompactCom 40 Software
Design Guide for further information.
12
LED colors
Get
struct of:
Value: Color:
UINT8 (LED1A)
01h Green
UINT8 (LED1B)
02h Red
UINT8 (LED2A)
01h Green
UINT8 (LED2B)
02h Red
13...
15
-
-
-
Consult the general Anybus CompactCom 40 Software
Design Guide for further information.
16
GPIO configuration
Get/Set
UINT16
Configuration of the host interface GIO pins. To enable
Transparent Ethernet, this attribute has to be set to
0002h during SETUP state.
Extended
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide